Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- How is battery storage integrated into a solar system?
Storage is integrated into a solar system on the DC side, with a hybrid inverter, or on the AC side, with a separate battery inverter. The choice defines the coupling, the backup during blackouts and the way the system is sized.
- How is bushing capacitance measured?
The capacitance of a condenser-type bushing is measured with a power factor or capacitance instrument, using the test tap, and is compared with the nameplate value and earlier measurements to detect short-circuited layers.
- How is calibration checked with a verification standard?
A device whose behavior is known and that was not used in the calibration is measured, and the results are compared with its reference values within the expected uncertainty; if they agree, the calibration is working.
- How is carbon monoxide measured in a workspace?
Carbon monoxide is measured with a specific electrochemical sensor, in the breathing zone and near combustion sources, and is interpreted by concentration and exposure time, because it is colorless, odorless and binds to hemoglobin, preventing oxygen transport.
- How is cell temperature measured during fast charging?
Cell temperature during fast charging is measured with thermocouples or NTC sensors attached to the hottest areas, with isolated acquisition and logging synchronized with the current.
- How is channel occupancy over time measured?
Channel occupancy over time is measured by observing, during a representative period, what fraction of the time the signal level exceeds a defined threshold, using an analyzer capable of gap-free capture or with adequate time resolution.
- How is charging integrated with solar generation?
Charging is integrated with solar generation through a meter at the point of connection that reports the surplus, so that the charger modulates its current to consume the available photovoltaic energy and makes up any shortfall from the grid.
- How Is Combustible Gas Content Measured?
The combustible gas content of oil is measured by extracting the dissolved gases from a sample and separating them by gas chromatography, with detectors that quantify hydrogen, hydrocarbons and carbon oxides against calibrated standards.
- How is common-mode current measured on a cable?
A current clamp is placed around the complete cable, with all its conductors inside, and read on a receiver or analyzer. Because differential currents cancel inside the clamp, the reading corresponds to common mode only, converted using the transfer impedance of the clamp.
- How is compliance of a grid interconnection verified?
It is verified by confirming that the system meets the technical requirements of the grid and the applicable regulations: connection and disconnection protections, quality of the injected power, metering and documentation, through testing and a review of the configuration.
- How is component temperature measured to locate a defect?
Measuring component temperature helps locate a defect because almost every electrical failure changes the power dissipated, and local heat points to the element dissipating more or less than normal.
- How is conducted disturbance measured on a power network?
The equipment is connected to the network through a line impedance stabilization network (LISN), which presents a defined impedance and delivers to the receiver the disturbance voltage of each conductor with respect to ground, using the detector and frequency range set by the applicable standard.
- How is conductor size selected by ampacity and short circuit?
A conductor's size must meet three conditions at once: its ampacity must handle the load current under the installation conditions, the voltage drop must be acceptable, and it must thermally withstand the short-circuit current until the protection clears it.
- How is continuous monitoring carried out during the work?
Continuous monitoring during the work is carried out by keeping a switched-on, verified multi-gas detector in each entrant's breathing zone, with alarms active, readings recorded and one clear rule: on an alarm, get out first and investigate afterward.
- How is cross-polarization measured?
Cross-polarization is measured by recording the antenna pattern with a probe of the same polarization as the antenna (co-polar) and then with an orthogonal probe, and comparing the two levels in each direction.
- How is current measured on busbars with flexible coils?
To measure current on busbars with flexible coils, the Rogowski coil is wrapped around the busbar, the coupling is closed and the coil is connected to an integrator that converts the signal proportional to di/dt into a signal proportional to the current.
- How is current unbalance measured in a three-phase feeder?
Current unbalance in a three-phase feeder is measured by recording the three phase currents simultaneously, and it is expressed as the deviation from the average or, more rigorously, as the ratio between the negative-sequence and positive-sequence components.
- How is DC surge protection designed?
DC surge protection is designed by identifying the paths through which surges enter, installing protection devices suited to the array voltage, minimizing loop areas in the wiring and ensuring equipotential grounding.
- How is differential pressure measured across a filter?
Differential pressure across a filter is measured with two taps, one before and one after the filter element, connected to a differential sensor; the difference grows as the filter gets dirty and is a guide to when to replace it.
- How Is Dissolved Gas Analysis Interpreted with the Ratio Method?
The gas ratio method interprets a dissolved gas analysis by comparing proportions between characteristic gases, not their absolute values, to classify the probable fault: partial discharge, low- or high-energy discharges, or thermal fault.
- How is electric stress distributed between the layers of an insulation system?
When several insulation layers are in series, the AC electric field is distributed inversely to the permittivity of each layer, so the layer with the lowest permittivity carries the highest field. Under direct current, the distribution is determined by the resistivities.
- How is electrical predictive maintenance planned?
Electrical predictive maintenance is planned by identifying which equipment is critical, how it fails, which measurable variable anticipates each failure, and how often it should be measured in order to act before the failure occurs.
- How is electronic equipment for vehicle use tested?
Electronic equipment for vehicles is tested by combining environmental tests, such as temperature, vibration and humidity, with electrical power supply and electromagnetic compatibility tests that reflect the conditions of the onboard electrical system.
- How is EMC addressed in battery-powered equipment?
It is addressed as in any other equipment, by identifying sources, coupling paths and victims, with the difference that no mains supply is connected in normal use, while switching converters, a charger and cables acting as antennas are present.
- How is EMC applied in electric vehicle design?
In an electric vehicle, electromagnetic compatibility is applied from the design stage because the traction inverter, the charger and the converters switch high currents and coexist with radio, sensors and data networks inside the same vehicle.
- How is energy lockout/tagout performed?
Energy lockout/tagout consists of isolating all of a machine's energy sources, fitting a device that prevents re-energizing it, identifying it with a tag and confirming that it is actually de-energized before work begins.
- How is envelope analysis performed for bearings?
The vibration signal is filtered in a high-frequency band where the defect impacts excite resonances, the envelope of that signal is obtained, and its spectrum is calculated, in which the defect repetition frequencies appear.
- How is equipment prepared for an emissions test?
It is prepared by fixing a representative, reproducible configuration: operating modes that produce the highest emission, cables and peripherals arranged as in normal use, software that exercises all functions and complete documentation of what is being tested.
- How is error vector magnitude measured?
Error vector magnitude (EVM) measures, on a vector analyzer, how far the received symbols fall from their ideal positions in the constellation, and it is expressed as a proportion of the reference amplitude.
- How is furan content in oil measured?
Furans in oil, such as 2-furfural, are measured by extracting them from the oil and analyzing them by liquid chromatography with an ultraviolet detector; their presence reflects thermal degradation of the cellulose in the insulation.