What it means
An antenna designed for one polarization, for example vertical linear, also radiates some of the orthogonal polarization. The desired component is the co-polar one and the unwanted component is the cross-polar one, or cross-polarization. Their ratio, in decibels, measures the purity of the polarization and determines how much is lost or interfered with when the system depends on it.
Measurement method
- Install the antenna under test on a positioner with a probe antenna of known linear polarization, in the far field.
- Align the probe with the expected polarization of the antenna and record the pattern: this is the co-polar pattern.
- Rotate the probe 90 degrees about its propagation axis so that it is orthogonal, and repeat the same sweep: this is the cross-polar pattern.
- Subtract the two patterns at each angle.
Another option is to keep the probe fixed and rotate the antenna under test about its axis; the rotating-probe method records the complete polarization pattern and makes it possible to determine the axis and the ellipticity.
What to watch for
- Probe purity: the probe itself has finite cross-polarization, and this limits the lowest value that can be measured.
- Angular alignment: a small rotation between the two polarizations mixes components and masks low values. The cross-polar component is very sensitive to this error.
- Reflections: echoes can rotate the polarization and raise the apparent cross-polar level.
- Dynamic range: the cross-polar level is usually far below the co-polar level, so the receiver must have margin above noise.
How to interpret the result
The most relevant value is not always on the axis of the main lobe. In many antennas, cross-polarization worsens off axis, so it is advisable to look at its behavior across the entire beamwidth and not only at the maximum. In a practical link, polarization discrimination helps separate channels, but multipath and propagation can degrade it.