Two worlds of testing
Testing vehicle electronics involves two groups of tests that complement each other. One is environmental and mechanical: the equipment endures heat, cold, vibration and humidity. The other is electrical: the onboard electrical system has variations, disturbances and noise that the equipment must tolerate without failing.
Onboard electrical tests
A vehicle’s power supply is not a stable source. During cranking the voltage drops; transients appear when inductive loads are disconnected; a discharged battery or a faulty alternator changes the voltage level; and reversed connections are possible. The equipment is tested with voltage profiles that reproduce these situations, and it is verified that it keeps its function or recovers without damage.
Electromagnetic compatibility
There are two questions. One is emissions: the equipment must not generate interference that affects other systems, such as the radio or sensors. The other is immunity: it must keep working in the presence of radio-frequency fields, electrostatic discharges and transients coupled onto the cables.
Environmental tests
- Temperature: operation in cold and heat, and cycling, in which components and solder joints undergo fatigue.
- Vibration: with profiles that depend on where it is installed: engine, chassis or cabin.
- Humidity and water: condensation, splashing and, depending on the location, protection against jets.
- Chemical: exposure to vehicle fluids.
How function is evaluated
Functional states are defined: normal, degraded and failed. For each test, the state that is allowed is established. Equipment that resets during a transient may be acceptable in a comfort system and unacceptable in a safety system.
How it is planned
The selection of tests and levels comes from the customer, the type of equipment and its location. The current edition of the applicable specifications is confirmed. Tests on real vehicles or on a bench with a network simulator complement the laboratory tests. Measurements involving the vehicle’s electrical system, especially in electric vehicles with high voltage, are carried out by qualified personnel in accordance with applicable safety regulations.