24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

How is common-mode current measured on a cable?

A current clamp is placed around the complete cable, with all its conductors inside, and read on a receiver or analyzer. Because differential currents cancel inside the clamp, the reading corresponds to common mode only, converted using the transfer impedance of the clamp.

Why it is measured

Common-mode current on a cable is the most frequent cause of radiated emission from cables and a good indicator of the problem. Measuring it shows whether a cable is the antenna, which frequencies it carries and whether a ferrite or filter actually reduces it, all without using a test chamber.

How it is done

  1. Choose the suspect cable; it can be the power cable, a data cable or a motor cable.
  2. Open the clamp and close its core around the complete cable, with all the conductors together. If only one is enclosed, the signal current is measured as well.
  3. Connect the clamp output to a spectrum analyzer or receiver.
  4. With the equipment in its normal operating mode, record the spectrum.
  5. Convert the voltage reading to current using the transfer impedance of the clamp, given in its certificate: in decibels, the current in dBµA is the voltage in dBµV minus the transfer impedance in dBΩ.
  6. Move the clamp along the cable and repeat.

Position along the cable

Common-mode current is not constant along the cable. On a long cable, current maxima and minima form, depending on the frequency and the terminations. A measurement at a single point can underestimate the maximum, so it is advisable to move along the cable, or always measure at the same position when the goal is to compare before and after a correction.

How to interpret the result

  • A peak at the frequency of the radiated problem indicates that the cable is the antenna.
  • A reduction after adding a ferrite shows that the ferrite acts on that mechanism.
  • A high current that is not reflected in the radiated emission suggests that another path dominates.

Limitations

The clamp can saturate with large low-frequency currents, such as that of a power cable under load; for this case, clamps designed to tolerate mains current are used. Measuring on cables connected to mains or power voltage requires qualified personnel following the applicable safety regulations. The measurement is relative; it is not equivalent to a standardized test, but it effectively guides the correction work.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer