Why it is needed
A defect on a race or a rolling element produces a brief impact each time it passes through the load zone. These impacts are weak and repeat at a low frequency, so in the early stages they remain hidden in the normal spectrum beneath the vibration from other sources. But each impact excites resonances of the structure and the sensor at high frequencies, where there is almost no other vibration. The amplitude of that high-frequency vibration appears modulated by the repetition frequency of the impacts.
Steps
- Measure with a rigidly mounted acceleration sensor with a wide high-frequency response.
- Apply a band-pass filter around a resonance where the impacts stand out from the noise.
- Rectify the filtered signal and obtain its envelope, or demodulate it.
- Calculate the spectrum of the envelope.
- Compare the peaks with the bearing defect frequencies.
Defect frequencies
They depend on the bearing geometry and the rotating speed: the ball pass frequency of the outer race and of the inner race, the rolling element spin frequency and the cage frequency. They are calculated from the bearing data or taken from the manufacturer’s databases.
How the results are interpreted
- A peak at the outer race frequency and its harmonics points to that defect.
- For the inner race, it is common to see sidebands at the rotating speed, because the defect enters and leaves the load zone.
- Growth in the level and in the number of harmonics suggests that the damage is progressing.
Limitations
- The choice of filter band determines the result; a poorly chosen band hides the defect.
- Gears and other impact sources also appear in the envelope.
- Slippage of the rolling elements makes the actual frequencies differ somewhat from the calculated ones.
- A bearing with no fault may show some signal because of lubrication or load.
The result is confirmed with trending, temperature, lubricant analysis or inspection.