What occupancy means
It is the proportion of time during which a channel is in use. It is calculated as the time the signal exceeds a threshold divided by the total observation time. It is an indicator of congestion: a very busy channel leaves little room to transmit, even if the individual signal level is low.
How it is measured
- Set the channel. Center frequency and width to observe.
- Choose the threshold. It must sit above the noise floor with some margin, but below the weakest signals of interest. A threshold that is too low counts noise as occupancy; one that is too high misses weak transmissions.
- Capture over time. With a real-time analyzer or an analyzer in zero-span mode, the channel power is logged with enough time resolution to see the shortest bursts expected.
- Observe a representative period. Occupancy changes with the hour, the day and the activity. A capture of a few seconds can be misleading.
- Calculate and present. The fraction of time occupied and, if of interest, the distribution of transmission durations and idle intervals.
The spectrogram as support
The spectrogram shows frequency on one axis, time on the other and level in color. It shows at a glance whether the channel is occupied by a continuous signal, periodic bursts or sporadic transmissions, and whether several systems are sharing it.
How to interpret the result
- High occupancy with very short bursts usually indicates many devices each transmitting little; the problem is contention for access.
- High occupancy with a continuous signal points to a single dominant transmitter.
- Low occupancy but with high levels in brief bursts can damage a sensitive link even if the average looks low.
Occupancy alone does not distinguish whether the signal belongs to your own system or an outside one. For that, the signal must be demodulated or identified by its spectral and temporal shape.