Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- How Is an Antenna Used in Emissions Testing?
In emissions testing, the antenna acts as a transducer that converts the field radiated by the equipment under test into a voltage a receiver can measure; its antenna factor is used to calculate the field strength, which is compared with the limit.
- How is an apparent soil resistivity curve interpreted?
An apparent resistivity curve shows how the measured resistivity changes as the electrode spacing increases; its shape indicates whether the ground becomes more or less resistive with depth, but the apparent value is not the true resistivity of any layer.
- How Is an Applied Voltage Test Performed?
In an applied voltage test, the insulation is subjected to a voltage above the service voltage, between conductors and ground, for a defined time; if there is no breakdown, the equipment passes.
- How is an arc flash study performed?
An arc flash study models how much energy an arc would release at each point in an installation, using system data and protective device trip times, in order to define approach boundaries, protective equipment and improvements.
- How is an automotive component environmentally qualified?
An automotive component is environmentally qualified by defining its mission profile and location in the vehicle, and subjecting it to temperature, humidity, vibration, dust, water and chemical tests consistent with that profile.
- How is an EMC pre-assessment carried out in your own laboratory?
With basic instruments: near-field probes, a current clamp, a line impedance stabilization network and a spectrum analyzer. It serves to detect problems and compare corrections, but it does not replace the formal test; margin must be left for uncertainty.
- How is an emission source located with near-field probes?
A near-field probe connected to a spectrum analyzer is swept over the circuit, and the rise in level at the problem frequency is followed until the point of maximum level is found. That point marks the source or the element radiating it.
- How is an entry permit prepared?
An entry permit is prepared before going in: the space and the task are identified, hazards are assessed and controlled, conditions are measured, roles and rescue are assigned, and a responsible person authorizes the work in writing for a defined period.
- How is an entry rescue plan organized?
An entry rescue plan is organized before anyone goes in: who rescues and how are defined, retrieval systems are set up outside, rescuers are equipped, communication is secured and the plan is rehearsed, with no reliance on improvisation.
- How is an environmental qualification plan prepared?
An environmental qualification plan is prepared by defining the product and its life environment, the failure modes to uncover, the test sequence, the sample size, the acceptance criteria and the documentation of results.
- How Is an Excitation Current Test Performed?
The excitation current test applies a reduced alternating voltage to one winding, with the others open, and measures the current flowing in each phase and at each tap changer position in order to compare the pattern with references.
- How is an impact test performed to find natural frequencies?
The structure is struck with an instrumented hammer while an accelerometer records the response; the ratio of response to force, as a function of frequency, shows peaks at the natural frequencies.
- How is an indoor coverage survey performed?
An indoor coverage survey consists of measuring how the radio signal is distributed inside a building and comparing it with what the service needs, in order to find weak areas, interference and points where antennas should be installed or relocated.
- How Is an Installation Verified Before It Is Energized for the First Time?
Before first energization, you verify that the actual installation matches the design, that it is well built, and that de-energized and functional tests confirm it can be energized in stages safely.
- How is an instrument prepared for calibration?
Preparing an instrument for calibration means delivering it clean, complete, stable and without prior adjustment, along with information on its use, so that the calibration reflects how it really behaves and not how it was left after being handled.
- How Is an Instrument’s Calibration Interval Determined?
The calibration interval is not set by a universal rule: it is determined from the stability of the instrument, the risk of an incorrect measurement, its use and its history of results, and it is adjusted over time.
- How is an insulating oil spill handled?
An insulating oil spill is handled in this order: secure the area, stop the source, contain, recover, clean up, manage the waste, and report according to the applicable environmental regulations.
- How is an inverse-time overcurrent relay set?
An inverse-time overcurrent relay is set by choosing the pickup current, the curve, and the time multiplier so that it operates quickly on heavy faults, ignores normal load, and coordinates with neighboring devices.
- How is an Ishikawa diagram used for an electrical failure?
An Ishikawa diagram organizes the possible causes of an electrical failure into categories, like a fish skeleton, so they can be reviewed systematically instead of settling for the first idea.
- How is an oil result compared with the equipment history?
An oil result is compared with the equipment history by checking its trend against earlier samples taken under equivalent conditions, because what matters is the rate of change and whether the value is consistent with the load, the temperature and the interventions on the equipment.
- How Is an Oil Sample Transported and Stored?
An oil sample is transported and stored in its sealed container, protected from light and extreme temperatures, with no air space when it is for gas analysis, and it is analyzed as soon as possible to prevent its composition from changing.
- How is an onboard charger diagnosed?
Diagnosing an onboard charger involves comparing the AC input power with the DC output power, verifying communication with the station, and reviewing fault codes, temperatures and insulation.
- How is an open-field antenna measurement performed?
The antenna under test and a reference antenna are installed at far-field distance, on non-metallic supports and on clear ground, and ground reflection and ambient signals, the two main sources of error, are controlled.
- How is an oscilloscope used to debug a switching converter?
To debug a switching converter, the oscilloscope is used to observe the switching node, the inductor current and the output, looking for overshoot, ringing, noise and behavior that changes with load.
- How is an outdoor product validated?
An outdoor product is validated by identifying the environmental factors it will face, translating them into representative tests and verifying function and degradation after combined exposure.
- How is an RF test bench designed?
You start from what needs to be measured, define the frequency and power range, choose the chain of sources, filters, attenuators and receivers, and verify with a level diagram that each stage operates in its linear region and within its safe range.
- How Is an Unauthorized Transmitter Identified?
An unauthorized transmitter is identified by characterizing its signal with a spectrum analyzer, comparing it with what should exist in that band and locating it by direction of arrival and level variation.
- How is an underperforming module string located?
An underperforming module string is located by comparing equivalent strings under the same conditions, starting with monitoring data and continuing with voltage, current and I-V curve measurements, and with visual and thermal inspection.
- How is antenna gain measured with three antennas?
The three-antenna method obtains the gain of three unknown antennas by measuring the transmission between them in pairs and solving a system of three equations, without needing an antenna of known gain.
- How is battery capacity estimated with a controlled discharge?
Capacity is estimated by discharging the fully charged battery at constant current down to its cutoff voltage and integrating the current over time; the result in ampere-hours depends on the test current and temperature.