- What is a ground reference plane in EMC?
A ground reference plane in EMC is a large conductive surface that serves as a common potential reference and as a low-impedance return path for high-frequency currents, both in a design and in a test setup.
- What is a ground rod electrode and what types exist?
A ground rod electrode is a metal rod driven into the ground to dissipate current; the main types differ in material and construction: solid copper, copper-clad steel, galvanized steel, stainless steel and chemically filled rods.
- What is a grounding electrode?
It is the conductive element, buried or in direct contact with the earth, that disperses the current of the grounding system into the soil; it can be a rod, a plate, a conductor, a ring, a grid or the steel of a foundation.
- What is a grounding system and what does it do?
A grounding system is the set of buried conductors and electrodes that connects an installation to the soil; its function is to provide a safe path for fault currents and keep potentials under control.
- What Is a Hall Effect Current Transducer?
A Hall effect current transducer measures current from the magnetic field it produces, using a semiconductor sensor that generates a voltage proportional to that field, and it works with both alternating and direct current.
- What is a hazardous atmosphere?
A hazardous atmosphere is air in a space that can cause death, incapacitation, impairment of the ability to self-rescue, injury or acute illness through a lack or excess of oxygen, flammable gases or vapors, combustible dusts or toxic substances.
- What is a latent failure?
A latent failure is a defect that already exists but has not yet shown itself, or a protective function that has stopped working without anyone noticing until it is needed.
- What is a lightning surge transient in immunity testing?
It is a high-energy overvoltage of relatively long duration (microseconds to hundreds of microseconds) applied to the lines of a piece of equipment to simulate the indirect effects of lightning and switching operations on the network. Unlike fast bursts, it can destroy components.
- What is a line impedance stabilization network?
It is a device inserted between the power network and the equipment under test to provide a defined, repeatable impedance at the measurement frequencies, isolate the setup from network noise and deliver the disturbance from the equipment to a receiver.
- What is a lockout/tagout padlock?
A lockout/tagout padlock is a padlock designed to hold an energy-isolating device in a safe position, with a unique or controlled key and identification of the person who fits it.
- What Is a Log-Periodic Antenna?
A log-periodic antenna is a broadband antenna whose elements are scaled in a geometric progression, so that its properties repeat periodically with the logarithm of frequency and its behavior stays nearly constant over a wide range.
- What is a logic analyzer for debugging?
A logic analyzer captures the digital state of many signals at once over time and shows the sequence, timing and protocols of a system so that logic errors can be debugged.
- What Is a Loop Antenna for Magnetic Field Measurement?
A loop antenna is a conductive loop that, by induction, delivers a voltage proportional to the component of the magnetic field passing through its area, and it is used to measure magnetic fields over a range of frequencies.
- What is a low-capacitance active probe?
A low-capacitance active probe uses an input amplifier very close to the tip to present a small input capacitance, which loads the circuit lightly and preserves fast edges up to high bandwidths.
- What is a measurement cursor?
A measurement cursor is a line placed on the waveform to read the voltage or time value at that point; with two cursors you also get the difference between them.
- What is a mechanical calibration kit and which standards does it contain?
A mechanical calibration kit is a set of standards of known impedance (open, short, matched load and thru) with which a vector network analyzer corrects its systematic errors; each connector type and gender requires its own kit.
- What is a MEMS accelerometer?
A MEMS accelerometer is an acceleration sensor made of silicon with a microscopic structure that deflects under acceleration, and it measures that deflection electrically, generally through a change in capacitance, with a response down to zero frequency.
- What is a microbolometer?
A microbolometer is an uncooled thermal detector: each pixel is a small isolated membrane that is heated by infrared and changes its electrical resistance, which is converted into a signal.
- What is a microinverter?
A microinverter is a small inverter connected to one or two modules that converts direct current into alternating current right on the roof and lets each module work independently.
- What is a mixed signal oscilloscope?
A mixed signal oscilloscope combines the analog channels of an oscilloscope with the digital channels of a logic analyzer, so that all signals are captured with the same time reference and the same trigger.
- What is a motor control center?
A motor control center, or MCC, is a set of standardized units inside a modular enclosure that groups the starters, protections, and controls of several motors, fed from a common bus.
- What is a moving-coil velocity sensor?
A moving-coil velocity sensor is an electromagnetic transducer in which a coil moves within a magnetic field and, by induction, generates a voltage proportional to the vibration velocity, with no need for an external power supply.
- What Is a Multifunction Calibrator?
A multifunction calibrator is an instrument that generates electrical and process signals with good accuracy, such as voltage, current, resistance and sensor simulation, and sometimes measures these quantities, in order to calibrate and test other instruments.
- What is a multiple access system?
A multiple access system is the method that allows several users to share the same communication medium, dividing resources such as frequency, time, code or space among them without their signals destroying each other.
- What Is a Numerical Protection Relay?
A numerical protection relay is a microprocessor-based device that samples currents and voltages, converts them to numbers, calculates quantities and executes protection functions in software instead of through electromechanical mechanisms.
- What is a particle counter used for?
A particle counter measures how many particles are in a liquid and what size they are, normally by passing the fluid through a light beam and recording the signal from each particle that interrupts it; it is used to verify oil cleanliness.
- What is a passive probe and when is it not enough?
A passive probe is a cable with resistive attenuation and capacitive compensation, with no amplifier; it is enough for signals of moderate frequency and amplitude, and stops being enough when loading, bandwidth, reference or voltage level rule it out.
- What is a permit-required confined space?
A permit-required confined space is one that, besides being confined, contains or may contain a serious hazard, such as a hazardous atmosphere, a risk of entrapment or engulfment, or converging walls, and can therefore be entered only with written authorization.
- What is a portable oil tester?
A portable oil tester is a field instrument that uses an electrode cell and a high-voltage source to measure the voltage at which the oil breaks down dielectrically; portable units also exist for moisture and other rapid diagnostic tests.
- What Is a Power Meter with a Sensor Used For?
It measures, accurately and with traceability, the absolute power reaching a sensor, regardless of frequency selectivity; the sensor converts RF power into an electrical signal and the meter processes and displays it.