What is a low-capacitance active probe?

A low-capacitance active probe uses an input amplifier very close to the tip to present a small input capacitance, which loads the circuit lightly and preserves fast edges up to high bandwidths.

Why input capacitance matters

Any probe connected to a node adds its input capacitance. Together with the source impedance, it forms a low-pass filter: the greater that capacitance, the more the edge is rounded and the more the circuit’s operation is altered. As frequency rises, capacitance stops being a detail and becomes the dominant load, rather than the input resistance.

How an active probe reduces it

A unity-gain amplifier with a very high-impedance input, normally a field-effect transistor, is placed at the tip, isolating the measured node from the long cable running to the instrument. The cable, with its capacitance and loss, sits on the output side of the amplifier, which drives it at low impedance. The load the circuit sees is that of the amplifier and not that of the cable. As a result, the probe handles higher frequencies and disturbs the circuit less.

Trade-offs

  • Limited dynamic range: the amplifier accepts a bounded input swing and a DC offset range. A signal that exceeds them is clipped, or the probe is damaged.
  • Low maximum voltage: they are more delicate than a passive probe when it comes to overvoltages and electrostatic discharge.
  • Power: they need a power supply, which usually comes from the oscilloscope’s own interface.
  • Self-noise: the amplifier adds noise, which matters if the signal is small.
  • Cost and fragility of the tip and connection accessories.

When it is advisable

For fast digital signals, for high-impedance nodes such as clock lines or oscillator outputs, and for verifying the rise time of low-voltage circuits. On the other hand, it is no use for power or mains voltages, where a high-voltage or differential probe is called for.

What to check first

  1. That the signal plus the offset fit within the probe’s dynamic range.
  2. That the tip accessory is as short as possible for the test point.
  3. That the bandwidth of the probe and that of the channel are compatible with the edge you want to see.