The design idea
In a conventional antenna, such as a dipole, operation is concentrated around the frequency at which its dimensions are comparable to half a wavelength. A log-periodic antenna distributes elements of increasing length along a feed line. Each element resonates at a different frequency, and the dimensions and spacings are related by a constant factor. If the frequency is multiplied by that factor, the antenna behaves in a similar way, which is where the name comes from.
How it operates: the active region
At each frequency, only part of the antenna radiates effectively: the elements close to resonance. The shorter elements, toward the apex, act as directors, and the longer ones, toward the rear, act as reflectors. The active region moves along the antenna as the frequency changes. This allows the pattern and impedance to vary little within the design band.
Characteristics the engineer sees
- Wide bandwidth, with a ratio between the extreme frequencies much larger than that of a dipole.
- Moderate gain and a unidirectional pattern, with a good front-to-back ratio.
- Linear polarization, determined by the orientation of the elements.
- Small ripples in impedance and gain within the band, because the periodic repetition is not perfectly uniform.
What it is used for
Its bandwidth makes it suitable for sweeps in radiated emissions tests, for field strength measurements and for spectrum monitoring, where changing antennas at each frequency would be impractical. In some designs it is combined with biconical-type elements or with a horn to cover an even wider range.
Limitations
- Its gain is lower than that of a resonant antenna designed for a single frequency.
- Its overall length is set by the lowest frequency it must cover.
- The phase center moves with frequency, which affects measurements that depend on the exact distance.