How it works
Instead of bringing many modules in series to a single inverter, each microinverter is installed behind one or two modules. Right there it performs maximum power point tracking and conversion to alternating current. Microinverters are connected in parallel to an AC circuit that runs to the panelboard, so the long wiring in the array is AC rather than DC.
Why it is used
In a traditional string, the modules in series share the same current, so the weakest module constrains the rest. With per-module conversion, a shadow, uneven soiling or a module with a different orientation affects only its own unit. That is why they are often seen on small roofs, on roofs with several orientations, or where obstacles cast shadows.
Advantages and technical costs
- Per-module monitoring: you can identify which one is yielding less without walking the array.
- Lower DC voltage in the wiring, which reduces the risk associated with high-voltage strings.
- Localized failure: if one unit breaks down, the rest keep producing.
- More electronics exposed on the roof, with high temperatures and difficult access for replacement.
- More units and more possible points of failure per installed kilowatt.
What an engineer sees in practice
Each module’s production curve is compared with those of its neighbors. A microinverter reporting less energy under equal conditions suggests undetected shading, soiling or a degraded unit. If it stops communicating but total production does not fall, the problem is usually in the communication link and not in the conversion. It is also advisable to verify that the unit’s rated power is compatible with that of the module, since a higher-power module can cause clipping at moments of peak irradiance.
When it is not the best option
In a large, uniform plant without shading, the advantage of per-module control shrinks and the number of units can complicate maintenance. There, the simplicity of a few string inverters usually carries more weight. The decision depends on shading, orientation, roof access and the rapid shutdown requirements of the applicable regulations.
Notice
Any work on an energized PV array, with DC voltages that are not interrupted by opening a disconnect on the AC side, must be carried out by qualified personnel, following the applicable electrical safety regulations.