Menu

What is a lockout/tagout padlock?

A lockout/tagout padlock is a padlock designed to hold an energy-isolating device in a safe position, with a unique or controlled key and identification of the person who fits it.

Definition

A lockout padlock is used to physically prevent the operation of a switch, valve or other device that isolates the energy of a piece of equipment. It is complemented by a tag stating who fitted it, when and why. Its value lies in the fact that the person doing the work controls the key: nobody can re-energize without their participation.

Features that distinguish it from an ordinary padlock

  • Exclusive use: it is reserved for energy lockout only, so that its presence always means the same thing.
  • Identification: a distinctive color and space for a name, area or photograph, to show who it belongs to.
  • Controlled key: each padlock has a unique key or a registered key system, so that it cannot be opened with keys from another padlock.
  • Suitable materials: a body and shackle resistant to the environment and, in electrical areas, made of non-conductive materials when the environment calls for it.
  • Strength: it must withstand a reasonable forcing effort, so that removing it requires tools and is evident.

Accessories that make it usable

  1. Multi-lock hasps: they allow several people to fit their padlocks at the same lockout point.
  2. Covers and specific devices for circuit breakers, valves, plugs and push buttons.
  3. Tags: they warn that the equipment must not be operated and record the person responsible.
  4. Group lockout boxes: for tasks with many points and several workers.

Good practices

  • Each person uses their own padlock and keeps their own key.
  • The padlock is not lent or used as a storeroom padlock.
  • The lockout is applied at the isolation point, not at the start control.
  • After locking out, a check is made that the equipment does not start and that no voltage is present.

When it is not enough

The padlock does not replace verification of the absence of voltage, control of residual energy or the written procedure. Its effectiveness depends on these always being applied. These activities must be carried out by qualified personnel following the applicable regulations.