What it adds to an oscilloscope
A conventional oscilloscope shows the real waveform of a few analog channels. A mixed signal oscilloscope adds several digital inputs, each with a comparator that decides whether the signal is a one or a zero. These inputs are displayed as logic traces alongside the analog ones and are synchronized with a single trigger and a single time base.
What problem it solves
In an embedded system, behavior depends on the timing relationship between software and hardware: a select line going active, data being sent, a supply voltage dropping. With an MSO you can trigger on a pattern across several digital lines and at the same time see the analog waveform of a power supply or a sensor, and so find out whether a reset coincides with a voltage dip or with a specific transaction.
Typical features
- Pattern or logic event triggering on several inputs, in addition to analog triggers.
- Parallel and serial bus decoding using the digital lines.
- Configurable threshold for each input or group, matched to the logic family.
- Grouping of lines into a bus and display as a numeric value.
Limits
- Digital inputs only indicate a high or low state; they do not show amplitude, overshoot or noise. To study an edge, you have to look at an analog channel.
- The number of digital channels is smaller than on a dedicated logic analyzer, and the memory depth may be less.
- The sample rate and time resolution of the digital channels may differ from those of the analog ones.
- The cables and tips of the digital inputs have their own capacitance and inductance, which affect the circuit on very fast lines.
When it does not apply
If you work only with analog signals, or if you need dozens of lines with very deep memory and clocked state analysis, an MSO is not the natural tool. To decide between the two, compare the number of channels and the need to see the analog waveform.