- How is the insertion loss of a connector or adapter measured?
By measuring the S21 transmission through a calibrated direct connection and then with the component inserted; the difference is the insertion loss, which includes resistive loss and the effect of mismatch.
- How is the insulation between high voltage and chassis measured?
The insulation between high voltage and chassis is measured with an insulation tester that applies a DC voltage between each pole of the bus and the chassis, or by measuring the system's own voltages, and it is expressed as a resistance.
- How is the insulation of a current transformer tested in the field?
The insulation of a current transformer is tested in the field with the equipment de-energized and isolated, by measuring the insulation resistance between windings and to ground and, where possible, the capacitance and dissipation factor of the main insulation through the test tap.
- How is the insulation of a DC battery bank verified?
In a DC battery bank, insulation is verified with the system in service, using ground fault detection or the measurement of voltages to ground, because a floating system tolerates a first fault but not a second.
- How is the insulation of medium-voltage switchgear tested?
The insulation of medium-voltage switchgear is tested with the equipment de-energized, isolated and grounded, removing or isolating sensitive components, and measuring between phases and from each phase to ground.
- How Is the Insulation Resistance of a Medium-Voltage Cable Measured?
The insulation resistance of a medium-voltage cable is measured between each conductor and its grounded shield, with the cable de-energized and isolated at both ends.
- How Is the Insulation Resistance of a Motor Measured?
The insulation resistance of a motor is measured with the motor de-energized and disconnected from its supply cable, by applying DC voltage between the windings and the grounded frame.
- How is the insulation resistance of a PV array measured?
The insulation resistance of a PV array is measured by applying a test voltage between the live conductors and ground, with the array disconnected from the inverter, to detect leakage that indicates damage to cables, modules or connectors.
- How is the insulation resistance of an insulated tool measured?
The insulation resistance of an insulated tool is measured by applying a DC test voltage between the conductive part and the insulating coating and confirming that the leakage current is so small that the resistance comes out very high.
- How Is the Integrity of a Long Transmission Line Verified?
Return loss and insertion loss measurements across the whole band are combined with time-domain fault location, which shows where each reflection occurs along the line.
- How is the internal resistance of a cell measured?
The internal resistance of a cell is measured by applying a current step and dividing the change in voltage by the change in current, or with an AC signal of fixed or variable frequency.
- How is the internal temperature of the windings measured?
The internal temperature of the windings is measured directly with factory-installed fiber optic probes, or estimated with a thermal image indicator or a model that adds to the oil temperature an increment proportional to the load current.
- How is the isolation between ports of a divider measured?
By measuring the transmission between the two output ports with the input terminated in a matched load and the remaining ports loaded; the level of that transmission, in decibels, is the isolation.
- How Is the Isolation Between Two Nearby Antennas Measured?
Isolation is measured by connecting each antenna to one port of a network analyzer and measuring the transmission parameter between the two ports; the lower the transmission, the higher the isolation.
- How is the leak tightness of an enclosure measured after a test?
Leak tightness is measured by detecting the flow of a gas through the enclosure, whether by pressure decay, by flow change or with a tracer gas, and comparing it with the allowable leak criterion.
- How Is the Lightning Impulse Waveform Measured?
The waveform of a lightning impulse is measured with a voltage divider and a high-speed recorder, and is characterized by its front time, its time to half-value and its overshoot.
- How is the loss tangent of a printed circuit substrate measured?
The loss tangent of a printed circuit substrate is measured by exciting it with a high-frequency field and determining how much energy it dissipates relative to what it stores; at microwave frequencies, resonant methods are preferred for their sensitivity.
- How is the magnetic permeability of a material measured?
The magnetic permeability of a material is measured by exciting it with a known magnetic field and measuring the resulting induction, or through the inductance of a coil containing it or the change in a transmission line loaded with it.
- How is the moisture absorption of an insulator evaluated?
The moisture absorption of an insulator is evaluated by comparing the mass of a dry specimen with its mass after exposure to water or to a defined humid atmosphere, and it is expressed as the mass increase relative to the dry mass.
- How Is the Neutralization Number Measured?
The neutralization number is measured by titrating a portion of oil, dissolved in a solvent, with a standard alkaline solution until the equivalence point is reached; the result is expressed in milligrams of potassium hydroxide per gram of oil.
- How Is the Ohmic Contact Resistance of Power Circuit Breakers Measured?
The ohmic resistance of the contacts of a power circuit breaker is measured with a micro-ohmmeter that injects a high direct current and measures the voltage drop over four wires, with the breaker closed and de-energized.
- How is the operating temperature of an insulator determined?
The operating temperature of an insulator is determined by evaluating how its properties degrade over time at different temperatures, and setting the temperature at which it maintains an acceptable level throughout the expected life.
- How is the permittivity of a powder measured?
The permittivity of a powder is measured by compacting it or containing it in a sample holder of known geometry, measuring the effective permittivity of the mixture of particles and air, and correcting it with a mixing model to estimate that of the solid material.
- How is the permittivity of an insulating liquid measured?
The relative permittivity of an insulating liquid is measured in a guarded electrode cell: the capacitance with the liquid is determined and divided by the capacitance of the same cell empty or with a reference fluid, at controlled temperature and frequency.
- How is the power consumed by a traction motor measured?
The power of a traction motor is measured on the electrical side with a power analyzer whose bandwidth is sufficient for the inverter modulation, and on the mechanical side as torque times angular velocity.
- How is the power of a microwave signal measured?
With a power meter and a sensor suited to the frequency, level and type of signal, applying the calibration factor for the frequency and taking into account the match between source and sensor.
- How is the presence of combustible gases measured?
Combustible gases are measured with a catalytic, infrared or thermal conductivity sensor that reports the result as a percentage of the lower explosive limit, calibrated for a reference gas and sampled at several levels of the space.
- How is the quality factor of a resonator measured?
The quality factor of a resonator is measured from its frequency response, by dividing the resonant frequency by the half-power bandwidth, and then correcting for the effect of coupling to obtain the resonator's own unloaded quality factor.
- How is the reflection coefficient of a load measured?
With a network analyzer calibrated for one port at the load connector, measuring S11; the result is a complex number that can be viewed as magnitude and phase, VSWR, or impedance on the Smith chart.
- How is the relative water saturation of an insulating oil calculated?
The relative water saturation of oil is calculated by dividing the measured water content by the maximum solubility of water in that oil at the sample temperature and expressing the result as a percentage. It thus indicates how close the oil is to saturation.