How is the internal resistance of a cell measured?

The internal resistance of a cell is measured by applying a current step and dividing the change in voltage by the change in current, or with an AC signal of fixed or variable frequency.

A quantity that depends on the method

Internal resistance is not a single value. It includes the ohmic resistance of the electrolyte and conductors, plus slower phenomena such as charge transfer and diffusion. For this reason two methods can give different results without either being wrong: they measure different phenomena on different time scales.

DC pulse method

A current step is applied and the voltage change is measured: R = ΔV / ΔI. If the voltage is read almost instantly after the step, the result is mainly the ohmic part; if several seconds are allowed to pass, polarization is added and the value grows. This is the method closest to real behavior during traction, which is why the reading time must always be stated.

AC method

A small current is injected at a fixed frequency, typically in the kilohertz range, and the impedance is measured. It is fast and does not discharge the cell, so it is suitable for sorting on a production line. Impedance spectroscopy repeats the measurement at many frequencies and separates the processes by their time constant, in exchange for more complex equipment and model analysis.

Conditions that matter

  • Four-wire (Kelvin) measurement, so that cable and contact resistance do not enter the result.
  • Defined state of charge and prior rest.
  • Controlled temperature, because resistance increases greatly as the cell cools.
  • Fixtures with stable contact pressure on the cell terminals.

How to interpret the result

An isolated value is of little use. What is useful is the comparison between cells from the same lot, the trend over the cycles or the difference from the initial value. A sustained increase is a sign of aging and limits the available power and the heating. Measurements on traction cells must be carried out by trained people, avoiding accidental short circuits.