Measurement principle
An insulated tool has a working metal part and a coating that prevents current from reaching the hand. The test applies a DC voltage and measures the tiny current that manages to pass through the insulation. By Ohm’s law, a very low current corresponds to a very high resistance, which is what is expected of sound insulation.
What is actually tested
Resistance is not always the only thing tested. Many insulated tools are evaluated with the manufacturer’s dielectric tests, in which an AC voltage is applied and a check is made that no breakdown occurs. Measuring resistance with a megohmmeter is a complementary check, useful for seeing trends and detecting contamination or moisture.
General procedure
- Visual and tactile inspection: look for cuts, dents, burns and detached coating. A tool with visible damage is not tested; it is removed from service.
- Cleaning and drying: remove grease, dust and moisture, which can give false readings.
- Prepare the setup: connect one electrode to the metal part and another that wraps around the coating, for example a metal foil or a water bath with an electrode, depending on the method being followed.
- Apply the test voltage specified by the procedure and wait for the reading to stabilize.
- Record the value and the environmental conditions.
How to interpret the result
- A high, stable value indicates intact insulation.
- A low or falling value points to moisture, contamination or damage.
- Comparison with earlier measurements of the same tool is more informative than a single isolated figure.
Limitations
A resistance measurement does not guarantee that the tool will withstand the working voltage in a field condition, nor does it replace the dielectric tests defined by the product standard. Each tool must only be used within the voltage shown on its marking.
What to check first
Always start with the visual inspection and the tool’s marking. Work with the test voltage and with electrical risk must be carried out by qualified personnel following the applicable regulations.