Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • How Is the Remaining Life of an Old Feeder Assessed?

    The remaining life of a feeder is not measured with a single test: it is estimated by combining its load and fault history, the condition of its insulation and accessories, and the trend of the results over time.

  • How is the remaining life of paper determined from the oil?

    The remaining life of paper is estimated from the degree of polymerization of the cellulose; using the oil, an indirect estimate is made through furans, carbon oxide gases, moisture, and acidity.

  • How is the resistance of a transmission tower measured?

    The resistance of a transmission tower is measured with the fall-of-potential technique adapted to the tower's geometry, and it must be isolated from the effect of the shield wires, which place other towers in parallel.

  • How is the resistance of an electrode measured without disconnecting it?

    The resistance of an electrode can be measured without disconnecting it using methods that separate the electrode's current from the rest of the system, such as selective clamp measurement, or with a clamp that measures a closed loop.

  • How is the resistivity of an insulating oil measured?

    The resistivity of an insulating oil is measured by applying a DC voltage between the electrodes of a cell of known geometry at a controlled temperature, measuring the current after a fixed electrification time, and calculating the resistance using the geometric constant of the cell.

  • How is the resolution bandwidth selected?

    According to what you want to see: a narrower bandwidth separates nearby signals and lowers the displayed noise floor, but lengthens the sweep; a wider one sweeps quickly but merges signals and raises the noise.

  • How is the severity of a thermal anomaly classified?

    The severity of a thermal anomaly is classified by combining the temperature difference from a reference, the load at the time of measurement, the type of component and the consequences of its failure.

  • How is the shielding effectiveness of a material measured?

    The signal transmitted through a sample of the material is compared with the signal transmitted without it, in the same setup, and the difference in decibels is the shielding effectiveness. The most widely used methods are the coaxial line with a sample holder and the chamber with a window in which the sample is placed.

  • How Is the Short-Circuit Impedance Test Performed?

    The short-circuit impedance test shorts the terminals of one winding, applies a reduced voltage to the other until a current close to rated flows, and calculates the impedance from the measured voltage, current and power.

  • How is the signal on a line measured to detect an intermittent fault?

    To detect an intermittent fault on a line, the signal is recorded continuously or with event triggering, so that the instrument captures the anomaly when it occurs even if nobody is watching.

  • How Is the Slip of an Induction Motor Measured?

    The slip of an induction motor is measured by comparing its actual speed, measured with a tachometer, with its synchronous speed, which depends on the supply frequency and the number of poles.

  • How Is the Stability of a Reference Standard Verified?

    It is verified by comparing the results of successive calibrations and verifications of the standard over time, to estimate how much it drifts and whether that drift fits within what the uncertainty of the work allows.

  • How is the surface leakage current of an insulator measured?

    The surface leakage current of an insulator is measured by applying voltage and using a guard terminal to separate the current flowing over the surface from the current passing through the volume, or by monitoring in service the current that flows to ground through the insulator structure.

  • How is the temperature dependence of permittivity measured?

    The temperature dependence of permittivity is measured by placing the sample in a measurement fixture inside a temperature-controlled oven or chamber, and recording permittivity and losses at different temperatures, waiting for thermal equilibrium at each one.

  • How is the temperature of a shiny metal object measured?

    A shiny metal has low emissivity and reflects its surroundings, so it is measured by artificially increasing its emissivity with tape or matte paint, or the result is interpreted only qualitatively.

  • How Is the Temperature of an Operating Panel Measured?

    The temperature of an operating panel is measured mainly with infrared thermography and is interpreted by comparing similar components and phases with one another, at the actual load at that moment, not from an isolated absolute value.

  • How is the temperature of an overhead line measured from the ground?

    From the ground, an overhead line is measured with a telephoto-equipped camera, concentrating on connections and splices, and taking into account distance, wind, sun, conductor emissivity and viewing angle.

  • How is the thermal stabilization time of a sample determined?

    Thermal stabilization time is determined by measuring the temperature of the slowest point of the sample, normally its core, during a trial run, and observing when it approaches the target value within tolerance and stops changing appreciably.

  • How is the transfer impedance of a shielded cable measured?

    Transfer impedance relates the voltage induced in the inner circuit of the cable, per unit length, to the current flowing on the shield. It is measured with a triaxial setup and a network analyzer, and a lower value indicates a better shielded cable.

  • How Is the Uncertainty of a Calibration Estimated?

    The uncertainty of a calibration is estimated by identifying the sources of variation, expressing each one as a standard uncertainty, combining them according to a measurement model and multiplying by a coverage factor to obtain the expanded uncertainty.

  • How is the uncertainty of an indirect measurement evaluated?

    In an indirect measurement, uncertainty is evaluated by combining the uncertainties of the input quantities weighted by their sensitivity coefficients, which are the partial derivatives of the function that defines the measurand.

  • How is the validity of results ensured between calibrations?

    The validity of results between calibrations is ensured with intermediate checks, check standards, drift tracking, comparisons with other equipment or laboratories, and good conditions of use and storage.

  • How is the vibration of a structure evaluated?

    The vibration of a structure is evaluated by measuring the response with accelerometers sensitive at low frequency, identifying its natural frequencies and comparing the levels with the comfort, damage or operating criteria that apply to the case.

  • How is the volume resistivity of an insulator measured?

    The volume resistivity of an insulator is measured by applying a DC voltage between two electrodes across the thickness of the sample, measuring the current passing through its volume, and calculating the ratio using the geometry.

  • How is the Wenner method applied for resistivity?

    The Wenner method measures soil resistivity with four electrodes in line and equally spaced: the outer ones inject current, the inner ones measure voltage, and an apparent resistivity is calculated.

  • How is thermography used in a photovoltaic system?

    It is used to locate modules, cells, connections, and boxes with abnormal heating under good irradiance, comparing similar elements and distinguishing real heat from reflections of the sky and the sun.

  • How is thermography used in building and envelope inspection?

    It is used to see surface temperature differences on walls, roofs, and windows that reveal missing insulation, thermal bridges, air leaks, or moisture, always with a temperature difference between indoors and outdoors.

  • How is thermography used in electronics and circuit boards?

    It is used to see how heat is distributed on a running board, locate components dissipating too much or short circuits, and validate the thermal design, using close-focus optics because the targets are very small.

  • How is thermography used in refractory inspection?

    The temperature of the outer metal shell of furnaces, ladles, and ducts is measured; an area of the shell hotter than its surroundings indicates that the inner refractory lining is providing less insulation, due to wear, cracks, or loss of material.

  • How is thermography used on transmission lines?

    It is used to detect splices, clamps, connectors, insulators, and hardware with abnormal heating, viewing them from a distance from the ground, a vehicle, or an aircraft, and correcting for the effects of distance and surroundings.