How is the leak tightness of an enclosure measured after a test?

Leak tightness is measured by detecting the flow of a gas through the enclosure, whether by pressure decay, by flow change or with a tracer gas, and comparing it with the allowable leak criterion.

What it means for an enclosure to be leak-tight

An enclosure is leak-tight when the gas leakage through it is below a defined limit value. In practice no enclosure has zero leakage: what is specified is a maximum rate, and the measurement method must have a sensitivity clearly better than that limit.

Common methods

  • Pressure drop or decay: the part is pressurized or evacuated, isolated, and the change in pressure is observed. It is simple and quantitative for medium and large leaks.
  • Bubbles or immersion: the pressurized part is submerged in a liquid and bubbles are observed. It locates the leak but has low sensitivity and depends on the operator’s eyesight.
  • Tracer gas with a helium mass spectrometer: the part is filled or sprayed with helium and the instrument detects the gas passing through. It is the most sensitive method and can quantify very small leaks.
  • Flow change: measures the flow rate needed to maintain a given pressure.

Why it is measured after the test

The prior measurement sets a baseline. Thermal cycling, vibration or humidity can fatigue seals, crack welds or deform gaskets, and an enclosure that sealed before may stop doing so. The difference between before and after reveals the damage, even if the external appearance is normal.

What to watch in the measurement

Temperature variations alter the pressure of the trapped gas and can be mistaken for a leak, so it is advisable to stabilize the part thermally. A real leak must also be distinguished from outgassing of materials or gas absorbed in the walls, especially in vacuum methods. The test system itself must be verified with a calibrated reference leak.

How to interpret the result

A gradual increase in leak rate between measurements suggests progressive fatigue of a seal. A sudden jump points to a crack or a displaced seal. Locating the leak with a tracer helps decide whether the problem lies in the design, the process or the material. The acceptable limit depends on the function of the enclosure and is taken from its specification.