How is the operating temperature of an insulator determined?

The operating temperature of an insulator is determined by evaluating how its properties degrade over time at different temperatures, and setting the temperature at which it maintains an acceptable level throughout the expected life.

What operating temperature means

It is not the temperature at which the material melts or softens, but the maximum continuous temperature at which it retains, for a defined service life, properties above an acceptable criterion. It therefore depends on three decisions: which property to monitor, which value counts as end of life and how much service time is expected.

Accelerated thermal aging

Waiting for years is not practical. Specimens are aged in ovens at several temperatures above the service temperature, and the chosen property is measured periodically: dielectric strength, mechanical strength, elongation or another. The time each temperature takes to bring the property to the end-of-life criterion is recorded.

The Arrhenius model

Many chemical degradation processes accelerate with temperature following an exponential relationship. Plotting the logarithm of the end-of-life time against the inverse of the absolute temperature gives a straight line, provided the mechanism is the same. That line is extrapolated to lower temperatures to estimate the life at the service temperature. For the calculation, remember that the temperature is in kelvin.

Limits of extrapolation

  • If a different mechanism acts at high temperatures than at service temperatures, the line is misleading.
  • Humidity, oxygen, voltage and mechanical stress in combination can degrade the material more than heat alone.
  • Scatter between specimens calls for several per point to give statistically meaningful results.

What the engineer sees

The result is usually given as a temperature index or a thermal class referred to a lifetime and a criterion. The thermal classes of insulation systems are taken from the product standards. When the datasheet gives a value, you need to find out under which property and which criterion it was obtained, because the same material can have different values for electrical and mechanical properties.

When it does not apply directly

For severe thermal cycling, thermal shock or aggressive environments, isothermal aging does not cover the dominant mechanism and specific tests are needed.