Where each power is measured
A powertrain has three points of interest: the inverter DC input, the motor terminals and the shaft. Shaft power is torque multiplied by angular velocity. Electrical power at the motor is measured on all three phases. Comparing the three points gives the efficiency of the inverter, of the motor and of the whole assembly.
Why it is harder than measuring a 50 or 60 Hz grid
An inverter feeds the motor with pulse-width-modulated voltage: fast rectangular pulses whose useful component is the fundamental. The current is nearly sinusoidal, but the voltage contains a lot of high-frequency energy. An analyzer with low bandwidth or poor synchronization does not integrate correctly. An instrument designed for this task is needed, with fast sampling, and current sensors with sufficient response, along with short, shielded cables.
What is calculated
- Total and fundamental active power per phase.
- Fundamental frequency and slip or angle, depending on the motor type.
- Efficiency = mechanical power / electrical power, for motor and for inverter.
Mechanical measurement
An inline torque transducer and a speed sensor provide the mechanical power. They operate on a bench with a load machine. The coupling is aligned carefully, because poor mounting introduces vibration and torque errors.
How to interpret the result
Efficiency varies with the torque and speed point, so the usual practice is to build a map by covering many operating points at thermal steady state. It is advisable to separate inverter switching losses from motor copper and iron losses, because they are tackled differently.
The equipment involves high voltage and rotating parts; tests must be run by qualified people with guards and lockout procedures.