24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

How is the insulation between high voltage and chassis measured?

The insulation between high voltage and chassis is measured with an insulation tester that applies a DC voltage between each pole of the bus and the chassis, or by measuring the system's own voltages, and it is expressed as a resistance.

What insulation means in a floating system

The high-voltage network of an electric vehicle is not connected to the chassis. This means that a first fault to chassis does not cause dangerous current, but it also means that the insulation is the only barrier. Measuring it shows how much margin remains before a second fault closes a current loop.

Insulation tester method

With the system de-energized, a DC test voltage is applied between each pole of the bus (positive and negative, separately) and the chassis. The tester gives a resistance. Each pole is measured because a fault may be on only one of them. The test voltage must be compatible with the components: too high a voltage can damage connected semiconductors and capacitors.

Energized system method

Some standards and manufacturers provide for measuring the voltage between each pole and the chassis, with and without an added known resistance, and calculating the insulation resistance from that. This is the basis of what the vehicle’s own insulation monitor does.

How the result is expressed

In vehicles, the resistance is customarily normalized by the working voltage of the system, in ohms per volt, because a higher-voltage bus needs higher insulation to limit leakage current. The acceptance criterion comes from the applicable standard or specification and must be consulted in its current edition.

Conditions that change the reading

  • Moisture and dirt on connectors and surfaces.
  • Filter capacitors connected between bus and chassis, which require waiting for them to charge before reading.
  • Temperature: insulation improves as it warms up and degrades with condensation.
  • Connected components: it is advisable to measure with the subsystems separated in order to locate a drop.

The measurement involves high voltage and capacitors that can retain charge. It must be performed only by qualified personnel, with the system deactivated and its discharge verified, following the regulations and the manufacturer’s procedure.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer