Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • How is touch voltage measured in a real installation?

    Touch voltage in a real installation is measured by injecting a known current into the ground grid and recording the voltage between the touched structure and a reference on the ground that simulates the feet, after which the result is scaled to the expected fault current.

  • How is touch voltage measured on a metal enclosure?

    Touch voltage on a metal enclosure is measured between the enclosure and a reference point representing the floor where a person's feet stand, using an instrument with an impedance comparable to that of the human body, because the result from an ordinary voltmeter can be misleading.

  • How is transformer insulation resistance measured between windings?

    A DC voltage is applied between one winding and another, with the transformer de-energized and disconnected, and the reading is the resistance obtained by dividing that voltage by the small current passing through the insulation.

  • How is transmitter output power measured?

    The output power of a transmitter is measured by connecting it, through a suitable attenuator, to a power meter or an analyzer, which integrates the power within the signal bandwidth, and correcting for the path losses.

  • How is triaxial vibration measured?

    Triaxial vibration is measured with a three-axis accelerometer or with three sensors oriented in orthogonal directions, which makes it possible to record vibration in all three spatial directions at a single point and at the same time.

  • How is vacuum pressure measured?

    Vacuum pressure is measured with the sensor suited to the pressure range: diaphragm gauges in low and medium vacuum, thermal gauges in an intermediate range and ionization gauges in high vacuum; many of them depend on the type of gas.

  • How is vibration measured on a bearing housing?

    Housing vibration is measured by attaching a transducer, normally an accelerometer, as close as possible to the bearing load zone and in the relevant directions, because the housing is the path by which the defect signal arrives.

  • How is vibration monitored in a centrifugal pump?

    Vibration in a centrifugal pump is monitored by measuring at the motor and pump bearings, in the radial and axial directions, on a fixed routine and with the machine in comparable operating conditions, in order to watch the trend and detect faults.

  • How is voltage drop calculated in a feeder?

    Feeder voltage drop is calculated by multiplying the current by the effective impedance of the conductor, which combines resistance and reactance with the power factor, and it is expressed as a percentage of nominal voltage.

  • How is water distributed between oil and insulating paper?

    Water in a transformer is distributed between the oil and the paper according to a temperature-dependent equilibrium: the paper stores the vast majority and the oil only a fraction, so measuring the oil requires knowing the temperature in order to estimate how much moisture is in the solid insulation.

  • How is water in oil measured with coulometric Karl Fischer?

    In coulometric Karl Fischer, the water in the sample reacts with iodine generated electrolytically inside the cell, and the amount of water is calculated from the electric charge consumed, with no need for a prepared titrant. It is the suitable method for very low contents such as those in insulating oil.

  • How is water pumped with solar energy?

    In solar pumping, a photovoltaic array powers a controller or drive that runs the pump; water is stored in a tank instead of energy being stored in batteries. The flow rate follows the irradiance: more sun, higher pump speed and more water.

  • How Is Wireless Communication Validated in a Vehicle?

    To validate wireless communication in a vehicle, the performance of the radio is measured as installed in the complete vehicle, in motion and in operation, because the body, the antenna and the vehicle's own electronics change the result.

  • How Is Wireless Telemetry of Electrical Variables Done?

    Wireless telemetry of electrical variables is achieved by measuring with transducers or meters at the point of interest and sending their data by radio to a concentrator, without the radio ever touching the power circuit.

  • How server room temperature is monitored

    A network of sensors is placed at the points where air enters the equipment, not just at the air conditioning return, with continuous logging, alarms and trend review.

  • How should insulating gloves be cared for and stored?

    Insulating gloves are kept clean, dry and free of folds, away from sunlight, heat, ozone, oils and sharp objects, and are stored in a suitable container that keeps them in their natural shape.

  • How should you respond to an electrical accident?

    In an electrical accident the first priority is not to become another victim: cut the power or separate the person using insulating means, call for emergency help, assess breathing and pulse and begin resuscitation if needed.

  • How sinusoidal and random vibration tests are performed

    The sample is attached to a shaker with a fixture and vibrated with a sinusoidal signal, which sweeps or holds frequencies, or a random signal, which excites many frequencies at once, under accelerometer control.

  • How temperature distribution in a chamber is validated

    A grid of calibrated sensors is placed in the working volume, the chamber is stabilized, and the deviation and variation of each point from the setpoint are analyzed over a period long enough to reveal drift.

  • How temperature is measured in an industrial furnace

    It is measured with sensors placed where they represent the load or the process, not just the furnace air, and uniformity is verified with a multi-sensor survey. The sensor type depends on the range and the atmosphere.

  • How temperature uniformity is measured inside a chamber

    An array of calibrated sensors is placed in the working volume, the chamber is stabilized at the setpoint, and the difference between the hottest and coldest sensors at the same instant is calculated over a recording period.

  • How the rate of temperature change is measured in a chamber

    Temperature is recorded with sensors in the chamber air and on the sample during a ramp, and the slope is calculated over a defined interval, distinguishing the air rate from the rate the sample actually reaches.

  • How water splash resistance is tested

    The enclosure is sprayed with water from several directions, using a device and flow rate set by the standard, for a defined time, and it is then checked for water ingress and for continued operation of the equipment.

  • In-house rescue or external rescue?

    In-house rescue is carried out by the facility's own personnel, who are immediately available and know the space; external rescue is carried out by an outside service, with more experience but with a travel time. The decision depends on whether that time is compatible with the hazard in the space.

  • Induction Motor or Synchronous Motor in an Industrial Application?

    The induction motor is rugged, simple and self-starting, which is why it dominates industry; the synchronous motor runs at an exact speed, can correct power factor and is useful for large constant-speed loads, at the cost of more complex excitation and starting.

  • Infrared thermometer or thermal imaging camera?

    An infrared thermometer gives a single value averaged over an area, while a camera gives an image with one measurement per pixel; that is why the camera finds anomalies and the thermometer only confirms temperatures at points already identified.

  • Inhibited or uninhibited oil?

    An inhibited oil contains an antioxidant that delays its oxidation and extends its service life, whereas an uninhibited oil oxidizes sooner; the choice depends on the type of transformer and on whether the inhibitor can be monitored and replenished.

  • Inspection with open covers or through windows?

    Opening the covers gives the most direct image but exposes personnel to energized equipment; infrared windows allow inspection with the cover closed, at the cost of part of the radiation being attenuated and having to be compensated for.

  • Leather glove over a dielectric glove: when is it necessary?

    The leather glove is worn over the dielectric glove to protect it from cuts, abrasion and mechanical punctures, because insulating rubber is thin and vulnerable; leather on its own does not insulate.

  • Licensed or Unlicensed Band for an Industrial Link?

    A licensed band offers protection against interference and greater predictability, but with paperwork, cost and less flexibility; an unlicensed band is immediate and cheap, but shares the spectrum with other users, with no guarantee of quality.