What it deals with
CISPR 11 deals with radio disturbances generated by ISM equipment, which is equipment designed to generate or use radio-frequency energy for industrial, scientific, medical, domestic or similar purposes, other than for communications. Examples include induction furnaces, dielectric heating equipment, arc welders with high frequency, plasma generators and medical radio-frequency equipment.
Classification
| Category | General meaning |
|---|---|
| Group 1 | Equipment that generates radio-frequency energy needed for its own internal operation |
| Group 2 | Equipment that generates or uses radio-frequency energy in the form of electromagnetic radiation, for example to treat materials |
| Class B | Equipment suitable for use in domestic environments and connected to networks that supply residential buildings |
| Class A | Equipment suitable for other environments, with less strict limits |
What it covers
- Conducted emission limits at power ports.
- Radiated emission limits, with different methods depending on the size of the equipment and on whether it is measured at a test site or in situ.
- Specific provisions for large equipment that cannot be brought to a laboratory, which is evaluated at its place of installation.
- In Group 2, part of the radiation is intentional, so the requirements take the function of the equipment into account.
When it does not apply
Some industrial equipment with power electronics has its own product standard setting its electromagnetic compatibility requirements, such as adjustable-speed electric drives. Before applying CISPR 11, verify which standard applies to the product. Likewise, CISPR 11 deals with emissions; immunity is addressed in other standards.
Current edition
The limits and the definitions of classes and groups have been revised, and their legal application depends on the country. Consult the current edition and the reference in your regulations before planning the test.