Shielding, filtering or separation: which works best for each problem?

It depends on how the disturbance couples: shielding addresses field coupling into or out of the enclosure, filtering acts on what travels along the cables, and separation reduces coupling between nearby circuits. The choice is based on the path identified, not on the tool at hand.

First the path, then the tool

All interference has a source, a coupling path and a receiver. The three techniques act on the path. A poor choice costs weight, money and time, so it pays to identify where the disturbance passes before adding components.

Technique Coupling it addresses Limitation
Shielding Radiated fields between the equipment and the outside; field coupling between modules Apertures and the cables passing through it defeat it
Filtering Disturbances conducted along power and signal cables Does not stop what couples through the field; needs a good ground
Separation and layout Capacitive and inductive coupling between nearby traces, cables and modules Requires space; does not work for very strong sources

How to recognize the path

  • If the emission changes when a cable is moved or disconnected, the problem travels along the cable: filtering or a ferrite.
  • If the emission remains with all cables disconnected and changes when covers are closed or opened, the enclosure is part of the path: shielding and joints.
  • If the effect depends on the distance between two cables or modules and decreases as they are moved apart, the coupling is local capacitive or inductive coupling: separation, orientation or perpendicular crossing.

Why they complement each other

A perfect shield with an unfiltered cable is of no use: the cable conducts the disturbance to the outside and acts as an antenna. An excellent filter in an enclosure with open seams does not help with a source radiating inside either. In practice, the solution is usually a combination in which each technique works where it belongs, together with good grounding.

And before any of them

Reducing the source is usually more economical: slower edges, smaller loops, less clock activity. Addressing the source lowers the demand on everything else.