The central idea: give the discharge a path that does not pass through the logic
An electrostatic discharge is a very fast pulse with considerable energy concentrated in a very short time. It almost always enters through what the person touches: the connector shell, exposed pins or the cable. If that current has no preferred route to the chassis or the equipment ground, it finds one through the transceiver or the processor, and that is where the damage or reset occurs.
That is why protection is not an isolated component but a strategy: intercept at the connector, divert to the chassis and limit whatever gets through.
Usual layers of protection
- Shield and connector shell: the cable braid must be bonded to the chassis with a low-impedance termination around the entire perimeter, not with a long pigtail, because the inductance of a long wire cancels the benefit at these frequencies.
- Transient suppressors: TVS diodes or protection arrays, placed as close as possible to the connector. Their capacitance must be compatible with the signal speed, and their return must go to the chassis or to a low-impedance reference.
- Series elements: resistors, ferrites or common-mode chokes that limit the current reaching the integrated circuit.
- Galvanic isolation: transformers or isolators that separate the cable ground from the logic ground and withstand the potential difference.
Board layout
Trace inductance decides whether the suppressor works. The route from connector to suppressor to return should be short and direct, and the suppressor should come before any other component. A well-chosen suppressor that is far away, or that has a long via to ground, lets through a voltage spike that the IC does see.
Where chassis ground and signal ground are joined also matters. If the discharge current crosses the signal ground to reach the chassis, the circuit reference moves and failures appear even without physical damage.
What the engineer sees in the test
In an immunity test, contact and air discharges are applied to accessible parts. Typical results are: the port keeps working, it loses communication and recovers by itself, it needs operator intervention, or it is damaged. Each case is classified with the performance criterion defined for the product.
What to check first
- How the cable shield terminates at the chassis.
- The distance and route between the connector and the suppressor.
- Whether the suppressor return goes to the chassis or to signal ground.
- Whether the suppressor capacitance degrades the signal in normal operation.