Why an inverter interferes
A photovoltaic inverter converts the direct current from the panels into alternating current by fast semiconductor switching. That switching generates broadband noise and harmonics that extend up to the medium-wave and shortwave radio bands. The panels are large, have parasitic capacitance to ground and are connected with long wiring, which provides a path for common-mode current and an effective antenna.
Step 1: identify the path
- Listen to the radio with the inverter off and on, to confirm that it is the source.
- Try a battery-powered radio away from cables and one connected to the mains: if only the second one is affected, the path is conducted through the power supply.
- With a current clamp, measure the common-mode level on the DC cables, on the AC cables and on the ground conductor.
- Try the antenna in another position: if the noise changes greatly with distance from the solar array cables, there is radiation.
Step 2: act on the path
- Common-mode ferrites on the DC and AC cables, close to the inverter, clamped around outgoing and return conductors together.
- An additional line filter on the AC output, if it is confirmed that the noise travels that way.
- Routing: group the positive and negative conductors of the solar array to reduce the loop area, and do not form loops with excess cable.
- Ground: check that the ground connections of the inverter, the array and the metal structures are continuous and low impedance.
- Antenna and receiver: separate the antenna from the cables, orient it and, if possible, use a shielded coaxial feed line with ferrites.
What to consider
The improvement depends on the cause. If the inverter’s emissions exceed what is permitted for its category, the final fix may require the manufacturer to step in or the equipment to be replaced. It is also advisable to check the communication cables and loose connections, which sometimes produce intermittent noise through poor contact.
Safety
The DC cables of a solar array remain energized whenever there is light and cannot be disconnected like a normal load. Any work on the inverter, the conductors or the protective devices must be done by qualified personnel, in accordance with the applicable electrical regulations.