The frequency error of a transmitter is measured by comparing its actual frequency with the nominal one using an instrument with a stable time base, and it is expressed in hertz or in parts per million relative to the center frequency.

What frequency error is

A transmitter should emit at its nominal frequency, but its reference oscillator ages and changes with temperature and supply voltage. The frequency error is the difference between the measured frequency and the nominal one. It is usually given in parts per million because the oscillator tolerance is a fraction of the frequency, so the same oscillator produces larger errors in hertz at higher frequencies.

Why it matters

Excessive error shifts the signal out of the assigned channel, where it interferes with neighbors, or out of the receiver passband, so the receiver does not demodulate it well. In systems with orthogonal subcarriers or very closely spaced carriers, even a small error destroys orthogonality.

How it is measured

  1. The transmitter is connected to the instrument with appropriate attenuation.
  2. The instrument is set to measure the carrier frequency. For a modulated signal, the estimated center frequency of the demodulated signal is used, or the unmodulated carrier if the equipment allows a test emission.
  3. The reading is compared with the nominal value and the relative difference is calculated.
  4. This is repeated under the conditions of interest: after warm-up and at different temperatures and supply voltages.

The instrument has frequency error too

The accuracy of the measurement cannot exceed that of the instrument’s time reference. For that reason a good quality internal reference is used, or the instrument is synchronized to a more stable external reference. If the instrument’s reference is worse than or comparable to the tolerance being verified, the result is inconclusive. The instrument must also have a current calibration.

What is observed

Slow drift during warm-up is normal in uncompensated oscillators. Abrupt jumps point to power supply or mechanical problems. In the constellation, a frequency error appears as continuous rotation of the symbols.

How to interpret the result

The permitted tolerance is set by the system specification or the applicable regulation. It should be confirmed that it is met across the entire operating temperature range and not only under laboratory conditions.

We do real tests, on video! Watch them on our YouTube channel →