Definition
EIRP stands for equivalent isotropic radiated power. An ideal isotropic antenna radiates equally in all directions. A real antenna concentrates energy in certain directions, so in its direction of maximum radiation it produces more power density than an isotropic antenna fed with the same power. EIRP expresses this effect as a single figure: the power an isotropic antenna would need to match that density.
How it is calculated
In decibels, it is a simple sum:
EIRP (dBm) = transmitter power (dBm) minus cable and connector losses (dB) plus antenna gain (dBi)
The unit dBi indicates gain relative to the isotropic antenna. Cable losses subtract; antenna gain adds.
Why it is used
What matters for interference and exposure is not the power leaving the transmitter, but what actually reaches others in the direction of radiation. Two pieces of equipment with the same output power can have very different EIRP if they use different antennas. That is why regulators usually set limits in terms of EIRP, and also why equipment can comply with one antenna and stop complying when it is replaced by one of higher gain.
EIRP and ERP
Effective radiated power, ERP, uses a half-wave dipole as its reference instead of an isotropic antenna. Since a dipole already has gain relative to the isotropic antenna, the same system has an EIRP numerically greater than its ERP. You must verify which of the two each standard requires.
An example
A transmitter that delivers a certain power to a lossy cable and a high-gain directional antenna can have an EIRP greater than that of the bare transmitter. If the transmitter power is lowered by the same amount that the gain rises, the EIRP does not change, and neither does the range in the main direction, although the side lobes behave differently.
When EIRP is measured in the laboratory, the radiated measurement includes the antenna; the conducted measurement requires adding the declared gain and subtracting the losses.