How is adjacent channel power measured?

Adjacent channel power is measured by integrating the power in the transmitter's channel and in the neighboring channels with an analyzer, and it is expressed as the ratio between the two; it indicates how much energy spills outside the assigned channel.

What it measures and why it exists

A real transmitter does not confine all its energy to the assigned channel. Part of it spills into neighboring frequencies, especially when the power amplifier operates close to its non-linear region. The ratio between the power in the adjacent channel and that of the main channel quantifies this spillover. If it is high, the transmitter degrades neighboring users.

How it is measured

  1. Set up the main channel. Center frequency and an integration bandwidth equal to the system’s channel bandwidth.
  2. Define the adjacent channels. Their offset from the center and their integration bandwidth, which do not always match those of the main channel.
  3. Adjust the analyzer. The resolution bandwidth and the video filter must allow the side lobes to be seen clearly; the detector must be the right one for noise-like signals, normally RMS. Dynamic range is critical: the analyzer’s own spillover and noise must be clearly below what is being measured.
  4. Measure. The instrument integrates the power in each window and calculates the ratios.
  5. Evaluate under real conditions. With the operating signal and power, and at the extremes of the power and modulation range.

What causes the spillover

  • Amplifier compression and non-linearity, which generate intermodulation products.
  • Insufficient pulse-shaping filtering.
  • Oscillator phase noise, which widens the base of the signal.
  • Signals with a high peak-to-average power ratio that get clipped.

How to interpret the result

A value that worsens as the power rises points to amplifier non-linearity; backing off the power or linearizing improves the ratio. A value that does not change with power points more toward phase noise or the filter. It is normal for the two sides of the channel to differ if there is asymmetry due to amplifier memory.

The limits the transmitter must meet are set by the applicable standard or regulation, and they should be consulted in their current edition. If in doubt, verify that the analyzer is not adding spillover of its own by reducing the input with attenuation and observing whether the reading changes.