Why metal changes the rules
Metal is a good reflector. In a plant, the signal bounces off structures, tanks and machinery, and the receiver gets the sum of several paths with different phases. At some points it is reinforced and at others it cancels, so the strength can vary greatly over distances of a few centimeters. In addition, large obstacles create shadow zones.
Stages of a deployment
- Requirements: which devices will connect, what data they generate, what latency and availability each one requires, and whether there is moving equipment.
- Site survey: walk through the plant with measuring equipment to record signal level, noise and spectrum occupancy. This is done with the plant running, because noise changes with production.
- Design: place access points with line of sight to the critical areas, at a height that keeps them from being blocked by machinery, and with enough coverage overlap for a mobile device to pass from one to another without losing connection.
- Channel and power plan: prevent nearby access points from using the same channel and limit power so as not to spread interference.
- Antenna selection: directional antennas concentrate energy toward specific aisles or areas, and special-mount antennas withstand the environment.
- Validation: repeat the measurements with the system installed and verify performance at the most difficult points.
Decisions specific to metal environments
- Accept more access points at lower power rather than a few at high power.
- Use meshes or repeaters for areas without line of sight.
- Consider technologies in a different band if 2.4 GHz is saturated.
- Take care with the cabling and power supply of access points, as well as their protection against dust, moisture and vibration.
Common mistakes
- Designing only with a theoretical model without measuring at the site.
- Measuring with the plant shut down and discovering the operating noise later.
- Placing antennas behind structures for ease of installation.
- Not anticipating layout changes: machines move and the design must tolerate this.
Work on elevated structures or near energized installations must be carried out by qualified personnel in accordance with the applicable safety regulations.