How is an indoor coverage survey performed?

An indoor coverage survey consists of measuring how the radio signal is distributed inside a building and comparing it with what the service needs, in order to find weak areas, interference and points where antennas should be installed or relocated.

What is being sought

Indoor signal depends on the materials, the layout and the furniture, and it cannot be deduced from a floor plan alone. The survey measures reality and answers three questions: where there is enough signal, where quality is poor because of interference or echoes, and what to change to correct it.

How it is done

  1. Define the requirement. Which service is needed, what signal level and quality it demands, and in which areas. Without a requirement there is no way to say whether coverage is sufficient.
  2. Prepare the floor plan. The starting point is a scale plan with walls and areas of use. Materials with high attenuation are identified, such as reinforced concrete, metal and coated glass.
  3. Optional preliminary estimate. A simulation serves as a starting point, but it must be validated by measurement.
  4. Measurement walk. With a calibrated receiver and a suitable antenna, the space is walked while position and measurements are logged. The measurement antenna should resemble those of the real devices, and its height and orientation should be consistent with actual use.
  5. Measure more than the level. In addition to signal strength, the signal-to-noise or signal-to-interference ratio, the occupancy of neighboring channels and, where applicable, application performance, such as actual throughput or packet loss, are recorded.
  6. Produce maps and analyze. The values are plotted on the floor plan to locate gaps and overlaps between cells.

What is seen in the results

A high signal level does not guarantee good service: if there is co-channel interference, the signal-to-interference ratio is low and performance drops. A very low level in a corner may be due to a metal door or an elevator, not to distance. Areas with excessive overlap between antennas can cause frequent cell changes or interference between them.

What to check first

  • That the measuring equipment is calibrated and used with the right antenna.
  • That the measurement is made with the building in normal use, because people and furniture alter propagation.
  • That critical points are repeated to confirm repeatability.