Two ways of talking about strength
Signal strength can be expressed as received power at the receiver terminals, for example in decibels relative to one milliwatt, or as electric field strength in space, in volts per meter or its logarithmic equivalent. These quantities are related through the properties of the antenna, but they are not interchangeable without knowing them.
Measuring received power
An antenna is connected to the analyzer or receiver and the signal level is read. To obtain a meaningful value, the following must be known:
- The antenna gain or antenna factor at that frequency.
- The cable and connector losses.
- The resolution bandwidth used, because a wider detector integrates more noise and more signal.
- The detector type and averaging: a varying signal gives different readings with peak or with average.
To go from received power to field strength, the antenna factor is used, which relates the voltage at the terminals to the field that produces it.
Measuring the field with a probe
Isotropic field probes measure the total strength regardless of orientation, which is useful in exposure or field level assessments. They have a defined frequency and level range and do not distinguish which transmitter the signal comes from.
The RSSI indicator on equipment
Commercial radios report a received signal strength indicator. It is convenient, but it is an internal estimate, its accuracy and scale vary between manufacturers and it does not replace a calibrated measurement. It is useful for comparing positions with the same equipment, not for comparing different equipment.
What the engineer observes
When the antenna is moved a few centimeters indoors, the level varies because of multipath. That is why it is averaged over several positions or over a period of time. A high level does not imply good quality if there is interference, which is why it is accompanied by a measurement of the signal-to-noise ratio.