How Is an Unauthorized Transmitter Identified?

An unauthorized transmitter is identified by characterizing its signal with a spectrum analyzer, comparing it with what should exist in that band and locating it by direction of arrival and level variation.

The approach

Identifying a transmitter means answering three questions: what signal it is, where it is and whether it should be there. They are answered in that order, with a spectrum analyzer, suitable antennas and knowledge of the band’s allocations.

1. Detect and characterize

The band is observed with a spectrum view and a waterfall view to see continuous and intermittent emissions. For each signal, record the center frequency, occupied bandwidth, level, modulation type when recognizable and time pattern: continuous, bursty or periodic. These features work as a fingerprint. A typical bandwidth and spectral shape allow you to suspect the type of equipment, such as a data link, a telephony system or a repeater.

2. Compare with what is expected

Using the country’s frequency allocation table and the list of users and your own equipment, you decide whether the emission is legitimate. A signal in a free-use band may be perfectly legal even if it does not belong to the site; a signal in a band assigned to a specific service, when the site does not use it, deserves attention. Spurious emissions or intermodulation products from known transmitters are also ruled out before blaming a third party.

3. Locate

  • Level gradient: when moving with an antenna, the level rises as you approach the source.
  • Directional antenna: rotating it until the maximum is found gives a direction; fading caused by reflections can be misleading, so it is advisable to measure from several points.
  • Cross bearings: two or more directions taken from different sites intersect near the source.
  • Gain reduction: an attenuator helps avoid receiver saturation when the source is close.

What to do with the result

A record with frequencies, times, levels, captures and directions of arrival is the basis for action. If the emission is illegal or harmful, the procedure is to inform the telecommunications authority; blocking or jamming the signal on your own is not permitted. Once the equipment has been identified, the matter can be resolved with the person responsible: reconfiguring the channel, removing the equipment or regularizing its operation.

Common mistakes

  • Concluding that a signal is illegal without consulting the band’s allocation.
  • Measuring at a single point and accepting the direction as correct.
  • Not recording times, and losing the relationship with the emission pattern.
  • Mistaking a harmonic or an intermodulation product for an independent carrier.