What Causes Intermodulation at a Site with Several Transmitters?

Intermodulation at a site with several transmitters appears when signals of different frequencies mix in a nonlinear element and generate new products that can fall in a receive channel.

What happens

A linear element passes each signal without mixing it. When something is nonlinear, two signals at frequencies f1 and f2 also produce components at combinations of the two. Third-order products, such as 2f1 minus f2 and 2f2 minus f1, are the most troublesome because they fall close to the original carriers and often within the working band. If one of those products coincides with the frequency of a receiver at the site, that receiver hears a signal nobody transmitted.

Where it is generated

  • Transmitter amplifiers: when operating close to saturation, or when receiving the signal of another nearby transmitter at their output.
  • Receivers: an input stage overloaded by strong signals generates internal products.
  • Passive elements: oxidized or loose connectors, corroded metal joints, and rusty hardware and structures can behave like poor-quality diodes. This is known as passive intermodulation (PIM).

Why it matters at a shared site

On a tower with several transmitters close together, each one receives the power of the others on its antennas. That energy enters the output stages and mixes. The more carriers there are, the more combinations exist, and the number of products grows rapidly.

How it is recognized

The symptom is noise or interference in a receiver that does not correspond to any known emission. With a spectrum analyzer you can see products at frequencies that match the expected combinations. A practical test is to turn the transmitters off one by one: the product disappears when any of those generating it is turned off. In addition, a third-order product rises by about 3 dB for every 1 dB increase in carrier power, behavior that distinguishes it from an ordinary emission.

Common mistakes

  • Looking for the source outside the site without checking your own connectors and hardware.
  • Increasing power to overcome the interference, which makes the products worse.
  • Replacing a single receiver without checking the cause in the transmitters.
  • Ignoring the distance between antennas and the isolation between them.

How it is reduced

Isolation between antennas is improved, filters and isolators are added at the transmitter outputs, frequencies are planned so that products do not fall in receive channels, surplus power is reduced and deteriorated connections are repaired.