What a channel describes
The channel is everything that happens between the antennas: attenuation with distance, shadowing by obstacles, multipath echoes and changes due to movement. Each aspect affects the signal differently, and characterizing means measuring them separately.
Quantities obtained
- Path loss: how much power is lost with distance. It is obtained by measuring the received power at many points and fitting a model.
- Small-scale and large-scale variation: shadowing changes slowly with obstacles; fading changes with displacements on the order of a wavelength.
- Impulse response and delay spread: it shows how many echoes there are, with what delay and with what strength. It determines whether the channel is frequency-selective for a given bandwidth.
- Doppler spread and coherence time: how quickly the channel changes due to movement.
How it is measured
The typical method is sounding: the transmitter emits a known wideband signal with good correlation properties, such as a pseudorandom sequence or a frequency sweep. The receiver records the signal and, by comparing it with the original, estimates the channel response. There are time-domain and frequency-domain sounders, the latter using a vector network analyzer that measures the complex response at many frequencies.
Calibration removes the contribution of the equipment, cables and antennas; without it, the system is measured rather than the channel. It must be made clear whether the antennas are part of the channel or are excluded.
How to interpret the result
The delay spread and the signal bandwidth determine whether equalization or multicarrier modulation is needed. The coherence time determines how often the channel must be estimated. Path loss and variability are used to calculate the fade margin in the link budget.
The results belong to the environment measured. Extrapolating them to another building or another band requires care, because materials and wavelengths change the behavior.