What Does the IEEE 802.11 Family Define in General?

The IEEE 802.11 family defines how the devices of a wireless local area network communicate by radio: the physical layer, meaning modulation and channels, and medium access control, which governs who transmits and when.

General scope

The 802.11 family is a set of IEEE specifications for wireless local area networks, known commercially as Wi-Fi. It covers the two lower layers of the communications model: the physical layer and the medium access control sublayer. Anything above them, such as IP or applications, falls outside its scope.

What it specifies

  • Physical layer: modulation and coding techniques, bands and channel widths, spectral masks and the structure of frames over the air. Successive amendments have incorporated more efficient schemes, such as orthogonal multicarrier modulation, more antennas and wider channels.
  • Medium access control: the mechanism by which stations share the channel. It is based on listening before transmitting and avoiding collisions, with random waits and acknowledgments of receipt.
  • Local network functions: association of a station with an access point, authentication, roaming between access points, power saving and quality of service.
  • Security: authentication and encryption mechanisms at the wireless link level.

How it is organized

The base standard is extended with amendments identified by letters, which add new bands, speeds or functions. They are periodically consolidated into a revised edition. That is why saying “802.11” with no further detail is not enough: what matters for a piece of equipment is which amendments it implements, in which band and with which channel widths.

What the engineer sees

On a protocol analyzer you can observe management, control and data frames, with their timing and acknowledgments. On a signal analyzer you can measure the modulation quality of a transmitter and the spectrum it occupies. Conformance tests compare these measurements with the requirements of the standard and of local regulations.

When the standard is not enough

The standard defines how to communicate, not how much power is allowed or which channels may be used in a country. Those limits are set by national regulations. Commercial interoperability certifications are a process separate from the technical standard.

For the precise requirements of an implementation, consult the current edition of the standard and its amendments.