The joint depends on preload
A bolt works like a stretched spring: the clamping force, or preload, keeps the parts compressed and friction prevents them from moving relative to each other. As long as the external load does not exceed that friction, the joint behaves as a single piece. Loosening begins when that preload is lost or when the external force overcomes the friction.
Main mechanisms
- Transverse slip: vibration or side loads make the parts slip slightly on each cycle, and that movement can back the nut off.
- Embedding: the asperities flatten after tightening and the joint loses part of its tension.
- Relaxation and creep: soft materials, gaskets or paint under the joint yield over time.
- Thermal cycles: differential expansion between materials changes the tension.
- Incorrect tightening: low preload leaves the joint vulnerable.
What the engineer sees
Looseness in a machine’s base shows up as increased vibration, with multiple harmonics of running speed in the spectrum and sometimes subharmonic components. Phase differences between the machine and the base are detected, along with fretting marks around the joint and bolts with slack when torque is applied.
How it is prevented
- Apply the specified tightening with a calibrated tool and a defined procedure.
- Keep contact surfaces clean, flat and free of soft materials.
- Choose fasteners suitable for the stress and the vibration.
- Check the joint after the first hours of operation and periodically thereafter.
Correcting the cause of the vibration is also necessary: a bolt that repeatedly comes loose usually indicates an underlying problem.