Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- What is volume resistivity?
Volume resistivity is a material property that measures its opposition to the passage of current through its volume, independent of sample size; it is related to resistance through the geometry.
- What is waveform update rate?
The update rate is the number of complete captures an oscilloscope acquires and displays per second. The higher it is, the less dead time there is between captures and the more likely it is that rare, sporadic events will be seen.
- What measurement methods does the IEEE 81 guide describe?
The IEEE 81 guide describes how to measure soil resistivity, the resistance or impedance of grounding systems and surface potentials, including fall-of-potential methods and four-electrode arrays.
- What power quality does a data center require?
A data center needs a supply that keeps the voltage within the tolerance of the computing equipment at all times, with continuous backup, redundancy, and control of harmonics and grounding.
- What Procedures Does the IEEE 149 Standard Describe?
IEEE 149 describes antenna test procedures: how to set up, measure and report parameters such as radiation pattern, gain, directivity, polarization and impedance, and which field and installation conditions must be met.
- What range and span mean for an instrument
The range is the minimum and maximum values the instrument is calibrated to measure; the span is the difference between the maximum and the minimum. Together they define how accuracy and adjustments are expressed.
- What relative humidity is and how it affects electronics
Relative humidity is the ratio between the water vapor present in the air and the maximum the air could hold at that temperature. In electronics it promotes corrosion, leakage and condensation, and its absence promotes electrostatic discharge.
- What safety requirements does IEC 61010-2-030 set?
IEC 61010-2-030 is a part of the IEC 61010 safety series that adds particular requirements for equipment with testing and measuring circuits, supplementing the general requirements of part one of the series.
- What salt spray testing is and what it evaluates
Salt spray is an accelerated corrosion test that exposes a sample to an aerosol of saline solution in a controlled chamber, in order to compare the resistance of coatings and materials to a corrosive environment.
- What self-heating means in an RTD
Self-heating is the rise in temperature of the sensing element caused by the measuring current passing through it, which dissipates power in the element. It introduces an error that depends on the medium and the current.
- What Short-Circuit Calculation Method Does IEC 60909 Describe?
IEC 60909 describes a method for calculating short-circuit currents in three-phase AC networks based on an equivalent voltage source at the fault location, with no need for a prior load flow study.
- What specific risks exist in a confined space?
The specific risks of a confined space arise from the combination of an atmosphere that can become hazardous, uncontrolled energies, engulfment, physical and thermal conditions, and the difficulty of communicating with and rescuing someone inside.
- What test pressure is compared with operating pressure
Operating pressure is what the equipment withstands in normal service; test pressure is higher and is applied in a controlled way to demonstrate strength and tightness. They are not interchangeable.
- What the Arrhenius acceleration factor is
The Arrhenius acceleration factor expresses how many times faster a chemical or degradation process occurs at an elevated temperature than at the use temperature, according to an activation energy characteristic of the mechanism.
- What the IEC 60584 thermocouple standard covers
For letter-designated thermocouples (K, J, T, E, N, R, S, B), IEC 60584 sets out the electromotive force versus temperature functions and tables, along with the tolerance classes.
- What the IEC 60751 standard specifies for platinum sensors
The IEC 60751 standard covers industrial platinum resistance thermometers: it defines the resistance-temperature relationship, the tolerance classes and the general requirements for the sensor.
- What the ITS-90 scale defines and why it matters in thermometry
The International Temperature Scale of 1990 is the practical definition used to realize temperature in metrology: reproducible fixed points and interpolating instruments between them.
- What the triple point of water means
The triple point of water is the unique condition of temperature and pressure at which liquid water, ice and vapor coexist in equilibrium. Its temperature is a fixed reference point in thermometry.
- What zero and full-scale readings are
The zero reading is what the instrument indicates when the quantity is nil or equal to the lower limit of the range; the full-scale reading is what it indicates at the upper limit. Together they define the instrument's basic adjustment.
- When is a rectangular distribution used in uncertainty estimation?
A rectangular distribution is used when only the limits within which the value lies are known and there is no reason to think some values are more likely than others; the standard uncertainty is then the half-width divided by the square root of three.
- Why a leak test gives inconsistent results
A leak test is inconsistent almost always because what changes is not the leak, but the temperature, the volume or the equilibrium of the system. A real loss has to be separated from a thermal or instrumentation effect.
- Why a pressure transmitter shows a zero shift
A transmitter's zero shifts because of sensor drift, mounting position, temperature, previous overpressure or a blocked atmospheric reference. External causes are ruled out first, and only then is it adjusted.
- Why a thermocouple loses accuracy over time
A thermocouple drifts because its wire changes: the composition and structure of the alloys are altered by temperature, atmosphere and thermal cycling, and the voltage it generates no longer follows the table.
- Why an RTD shows error from its lead wires
The wires connecting the RTD to the meter have their own resistance, and the meter adds it to that of the sensor. With two wires that sum is an error; with three or four wires it is compensated or eliminated.
- Why do arc flash accidents happen in electrical panels?
Arc flash accidents in panels happen when something breaks down the insulation between phases or to ground, through contamination, tools, loose connections, wear or switching operations, and they get worse if the protection is slow to clear the fault.
- Why do buried electrodes corrode?
Buried electrodes corrode because moist soil acts as an electrolyte: the corrosion can be galvanic from dissimilar metals, or caused by stray currents, soil composition or differences in aeration.
- Why do camera readings drift over time?
Because the detector, electronics, and optics change slowly with use, temperature, and aging, and the relationship between signal and temperature calibrated at the factory no longer matches reality exactly.
- Why do cells break with microcracks?
Silicon cells are very thin, fragile wafers. Microcracks appear as a result of mechanical and thermal stresses during transport, installation and operation, and they can grow with cycling until they isolate areas of the cell that stop producing.
- Why Do Connection Points in a Panel Heat Up?
A connection heats up because its contact resistance is higher than intended, and the current passing through it generates heat proportional to that resistance and to the square of the current.
- Why do flexible test cables degrade VNA calibration?
Flexible test cables degrade the calibration of a vector network analyzer because, when moved, their electrical length, loss and match change, and calibration assumes those characteristics stay the same as when the standards were measured.