The mechanism
In a series string, all the cells carry the same current. If a cell can produce less current than the others, because of shading, damage or a defect, the rest force it to conduct more than it generates. That cell becomes reverse biased and turns into a load: it dissipates the power its neighbors produce across it and heats up locally.
Common causes
- Persistent partial shading, such as a chimney, a cable or bird droppings on a cell.
- Cells with microcracks or disconnected areas, which reduce their available current.
- Poor solder joints or internal connections that increase resistance and heat up through the Joule effect.
- Cells with low shunt resistance, that is, with local leakage, which concentrate current at one point.
- Mismatch between cells with very different characteristics within the same module.
The role of bypass diodes
Each module includes bypass diodes that provide an alternate path around a group of cells when one of them becomes reverse biased. They limit the reverse voltage and the heating, but do not eliminate it: before the diode conducts, the weak cell may already be dissipating. If the diode fails, the module loses that protection.
What the consequences are
Local heating can degrade the encapsulant, discolor the backsheet, melt solder joints and, in severe cases, damage the glass or start a fire. A mild hot spot can remain stable for years; an intense one gets worse over time, because the damage increases the resistance or reduces the current even further.
How it is detected
Infrared thermography with the module in operation and good irradiance shows areas hotter than their surroundings. It is complemented by the I-V curve and, in the laboratory, by electroluminescence, which reveals inactive or fractured cells. Interpretation must take into account the irradiance, the wind and the camera angle.
Notice
Any work on an energized photovoltaic array, with DC voltages that are not interrupted by opening a disconnect switch on the AC side, must be carried out by qualified personnel in accordance with the applicable electrical safety regulations.