Why does a bearing fail from poor lubrication?

A bearing fails from poor lubrication because, without a film separating the surfaces, metal-to-metal contact generates friction, heat and wear that damage the raceways and rolling elements until fatigue and cracks develop.

The role of the lubricant

In a healthy bearing, a very thin lubricant film separates the surfaces that roll under load. That film prevents direct contact between asperities, reduces friction and carries away heat. If the film is insufficient, the surfaces touch, friction increases and the material wears or fatigues sooner than expected.

What degrades it

  • Lack of lubricant: regreasing intervals that are too long or forgotten points.
  • Excess grease: causes churning, heating and increased friction.
  • Unsuitable lubricant: viscosity or additives that do not match the speed, load and temperature.
  • Contamination: dust, water or particles that break the film and scratch the raceways.
  • Degradation: oxidation or aging due to high temperature.
  • Mixing of incompatible greases.

What is seen in practice

The first symptom is usually thermal: the housing runs hotter than usual. In vibration, the high-frequency noise floor rises and, in the acceleration or envelope measurement, impacts appear from the surfaces that are starting to become damaged. Later, the characteristic raceway and rolling element defect frequencies appear, with sidebands. Abnormal noise may also be heard and debris may be seen in the grease.

How it is prevented

  1. Follow the manufacturer’s instructions on type, quantity and interval.
  2. Avoid over-greasing and regrease with the machine in the specified condition.
  3. Protect seals and breathers against contamination.
  4. Monitor temperature and high-frequency vibration as an early warning.

When it is not the cause

The same symptom can come from misalignment, excessive preload or incorrect fits, so the cause should be confirmed before changing the lubricant.