Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What is the noise floor?

    The noise floor is the power level below which a signal cannot be distinguished from the random fluctuations of the measurement system itself. It depends on thermal noise, the receiver noise figure and the measurement bandwidth.

  • What is the oil quality index?

    The oil quality index is a number that combines properties such as interfacial tension and acidity to summarize the degree of aging; its exact definition varies with use, so it must be verified.

  • What is the P-F curve?

    The P-F curve represents how a function deteriorates from the moment a defect becomes detectable (point P) until the equipment fails (point F); the time between the two points is the margin for action.

  • What Is the Percent Impedance of a Transformer?

    Percent impedance is the voltage that must be applied to the primary, with the secondary short-circuited, for rated current to flow, expressed as a percentage of rated voltage; it sums up the internal voltage drop and limits fault current.

  • What is the performance ratio of a solar plant?

    The performance ratio of a solar plant compares the energy actually delivered with what an ideal system would have produced under the same irradiation; it sums up the losses from temperature, soiling, wiring, the inverter and availability.

  • What Is the Permissible Temperature Rise in a Transformer?

    Permissible temperature rise is the increase in winding and oil temperature above ambient that the design allows at rated load, and it is set so that the cellulose insulation achieves its intended thermal life.

  • What is the phase center of an antenna?

    The phase center of an antenna is the point from which the radiated wave appears to emanate with spherical phase fronts; it is the correct reference point for measuring distances and aligning the antenna in phase measurements.

  • What is the phase noise of an oscillator?

    It is the measure of the random phase fluctuations of an oscillator, seen as noise sidebands around the carrier; it is expressed as power in a one-hertz band relative to the carrier, as a function of frequency offset.

  • What is the probe attenuation factor?

    The probe attenuation factor is the ratio between the voltage at the tip and the voltage reaching the oscilloscope input; the instrument uses it to scale the reading and display the actual voltage at the tip, which is why it must match the probe in use.

  • What is the reference plane in a measurement?

    It is the position along the signal path to which the results of a measurement are referred. Everything before that plane is corrected or excluded; everything after it is part of what is measured.

  • What is the rise time of an instrument?

    The rise time of an instrument is the time its output takes to go from a low reference level to a high one when it receives an ideal step, and it is related to its bandwidth: the greater the bandwidth, the shorter the rise time.

  • What is the RMS value in vibration?

    The RMS (root mean square) value is the measure of vibration amplitude that represents its energy content: the signal is squared, averaged over time and the square root is taken.

  • What is the Seebeck effect?

    The Seebeck effect is the appearance of a voltage in a circuit of two dissimilar conducting materials when there is a temperature difference between their junctions; it is the physical principle of the thermocouple.

  • What Is the Service Factor of a Motor?

    A motor's service factor is a multiplier of rated power that indicates how much additional load it can handle continuously, under rated voltage, frequency and ambient conditions, with acceptable heating.

  • What is the signal-to-noise ratio of a link?

    The signal-to-noise ratio compares the power of the useful signal with the noise power at the receiver; in a link it determines how well the signal can be demodulated and, with that, which data rate and error rate are possible.

  • What is the spectral range of an infrared camera?

    Spectral range is the band of infrared wavelengths to which the detector responds; it defines what can be measured, at what temperatures and through what media.

  • What is the standing wave ratio?

    It is the ratio between the maximum and minimum voltage of the standing wave that forms on a line when part of the signal is reflected at the load; it equals one with a perfect match and grows as reflection increases.

  • What is the temperature coefficient of a module?

    A module's temperature coefficient indicates how much an electrical quantity, normally power, voltage or current, changes for each degree of variation in cell temperature; for power it is negative in silicon.

  • What is the thermal class of insulation?

    The thermal class of insulation is the maximum continuous operating temperature that its insulation system tolerates while reaching an expected service life, and it is designated by a letter.

  • What is the time base?

    The time base is the oscilloscope's horizontal setting that sets how much time each screen division represents; it determines the visible time window and, on a digital instrument, the sampling rate used for capture.

  • What is the time constant of a temperature sensor?

    The time constant of a temperature sensor is the time it takes to cover about two thirds of a sudden temperature change; it indicates how quickly the sensor follows the medium, not how long it takes to stabilize completely.

  • What is the trigger on an oscilloscope?

    The trigger is the mechanism that decides the instant at which acquisition begins, so that every sweep starts at the same point on the signal; without a stable trigger, a periodic signal would appear shifted and blurred.

  • What Is the Vector Group of a Three-Phase Transformer?

    The vector group of a three-phase transformer indicates how its windings are connected, in delta, wye or zigzag, and what phase shift results between the high-side and low-side voltages, using a code of letters and a number.

  • What is thermal drift in an instrument?

    Thermal drift is the slow change in an instrument's reading or output when its temperature varies; it means having to wait for warm-up, control the environment or apply corrections.

  • What is thermal resolution or NETD?

    Thermal resolution, or NETD, is the smallest temperature difference the camera can distinguish from the noise of its detector; the lower it is, the smaller the differences it can show.

  • What is thermal runaway in lithium batteries and what causes it?

    Thermal runaway is a chain reaction in which the heat generated inside a cell accelerates reactions that generate more heat; it is caused by internal short circuits, overcharging, mechanical damage, overheating and manufacturing defects.

  • What is third-order intermodulation?

    It is the distortion that appears when two signals of nearby frequencies pass through a nonlinear device and generate products at 2f1−f2 and 2f2−f1, which fall next to the original signals and cannot be filtered out easily.

  • What is total demand distortion of current?

    Total demand distortion of current, TDD, is the root of the sum of the squares of the harmonic currents expressed as a percentage of the maximum demand load current, not of the instantaneous fundamental current.

  • What is transformer inrush current and what effects does it have?

    Energizing current, or inrush, is a transient magnetizing current far above rated current that appears when a transformer is connected and its core saturates, and it can cause protection trips, voltage sags and mechanical stresses.

  • What is vacuum pressure?

    Vacuum pressure is any pressure below atmospheric; it is better described as low absolute pressure than as “negative” pressure, and each vacuum level demands different sensors and precautions.