Electrical length and wavelength
What matters is not the physical length of the cable but its length compared with the wavelength of the signal. When the cable is very short relative to the wavelength, the current flowing through it produces a small far field. As its length approaches a fraction of the wavelength, radiation rises quickly, since the cable behaves like a dipole or a monopole.
Resonances
A cable excited by common-mode current resonates at the frequencies where its length matches multiples of a quarter or half wavelength, depending on its terminations. At those frequencies, the current along the cable reaches maxima and radiation is at its highest. A longer cable has more resonances distributed across the spectrum, and the first ones occur at lower frequencies.
What the engineer sees in practice
- Radiated emission peaks that shift in frequency when the cable length changes.
- Emission that decreases when the cable is shortened or gathered up, or when a ferrite is added to block the common-mode current.
- Peaks spaced almost regularly in frequency, corresponding to successive resonances.
Why loops also matter
A two-conductor cable forms a loop between the outgoing and return paths. The longer it is and the farther apart the conductors, the greater the loop area and the more magnetic field it produces or picks up with a differential current. With common-mode current, the cable behaves like a wire antenna relative to its surroundings.
Consequences for standards and testing
Because length alters the result, test standards define the length and arrangement of the cable in the test, and sometimes specify how much of the excess is folded. That is why a product used with cables longer than those tested can cause more problems in the field. In design, the preventive action is to filter or protect the cable exit so that common-mode current never reaches the cable.
When this does not apply
If the cable is well shielded with a 360-degree termination and the common-mode current is minimal, length loses importance, because the cable does not receive the energy that makes it radiate.