Definition
The RMS (root mean square) value is obtained by squaring each instant of the signal, calculating the average of those squares over an interval and taking the square root. This yields a single number that represents the effective amplitude of a signal that changes in sign and value.
Why it is used
The simple average of an alternating vibration is close to zero, because the positive and negative parts cancel out, and it says nothing about its intensity. RMS avoids that problem and is also tied to energy: the power associated with a signal is proportional to the square of its amplitude. That is why it is the usual measure for expressing overall vibration level and for applying severity criteria, normally in velocity.
Relationship with peak
For a pure sine wave, the peak value is the square root of two times the RMS, meaning the RMS is approximately 0.707 of the peak. That relationship is valid only for a sine wave. In a signal with impacts, the peak can be much greater than the RMS, and the ratio between them (the crest factor) is used as an indicator of impulsiveness.
What to keep in mind when reading it
- Overall RMS sums the energy of all frequencies within the measured band. A defect at a specific frequency can stay hidden if the rest dominates.
- It depends on the averaging time: brief events are diluted in long averages.
- It depends on the frequency band of the instrument’s filter.
- The quantity (acceleration, velocity or displacement) and the band must be stated when reporting it.
How to interpret the result
A sustained increase in RMS over the baseline signals a change in condition, but not its cause. To locate the cause, the spectrum and the waveform are used. For incipient bearing defects, overall RMS tends to react late, so it is complemented with peak indicators or with the envelope.