Definition
The electrical parameters of a module depend on the temperature of its cells. The temperature coefficient describes that dependence: how much a parameter varies for each degree of change. It is usually expressed as a percentage per degree or as an absolute unit per degree, and manufacturers publish it for maximum power, open-circuit voltage and short-circuit current.
Why temperature has an effect
As the semiconductor heats up, the bandgap narrows slightly. This raises the current a little, because more photons are absorbed, but lowers the voltage more markedly, because of the diode’s behavior. The net result for power is a decrease. That is why the power coefficient is negative in crystalline silicon modules.
How the three coefficients behave
- Open-circuit voltage: a negative coefficient with a large effect.
- Short-circuit current: a small, positive coefficient.
- Maximum power: a negative coefficient, determined mainly by voltage.
What it is used for
First, to correct measurements to a reference temperature: a curve measured in the field with hot cells is translated to reference conditions so it can be compared with the datasheet. Second, to estimate production: a hot module yields less, and in warm climates that loss is significant. Third, to size strings: open-circuit voltage rises in the cold and maximum power point voltage falls in the heat, and both extremes must fit within the inverter’s window.
What an engineer sees in practice
At midday, maximum power does not match the morning value even if irradiance is the same: the module is hotter. Cell temperature is higher than ambient air temperature and depends on irradiance, wind and mounting. That is why cell temperature is measured rather than air temperature.
How to interpret the value
A coefficient that is smaller in absolute value means the module loses less with heat. Exact values must be taken from the datasheet of the specific module. Electrical work on solar arrays must be carried out by qualified personnel.