What is the phase center of an antenna?

The phase center of an antenna is the point from which the radiated wave appears to emanate with spherical phase fronts; it is the correct reference point for measuring distances and aligning the antenna in phase measurements.

The idea

In the far field, the phase front radiated by an antenna resembles a sphere with a center. That center is the phase center. If the antenna were a point source, it would coincide with it. In a real antenna of finite size, the point is a property of the field, not a marked physical location, and it can lie inside the antenna, in front of it or behind it.

Why it does not coincide with the geometric center

The current distribution of the antenna determines how the phase contributions of its different parts combine. In a horn antenna, for example, the phase center lies inside the horn, near the throat or shifted toward the aperture depending on the plane and the frequency. In a log-periodic antenna it shifts as the frequency changes, because the active region moves along the structure.

What it depends on

  • Frequency: in broadband antennas it can vary considerably.
  • Direction: the phase center is not the same in all directions; it is usually defined over the portion of the pattern near the main lobe.
  • Plane considered: the electric and magnetic planes can have different centers.

Where it matters

  1. Gain measurement using Friis: the distance between antennas must be counted between phase centers, or an error appears in the gain, especially at short distances.
  2. Positioners: the rotation axis must be placed on the phase center so that the phase does not vary as the antenna rotates.
  3. Satellite positioning systems: precision antennas have a characterized phase center, and its variation is corrected to avoid errors in the calculated position.
  4. Reflectors: the feed must be located with its phase center at the focus.

What the engineer sees

A poorly placed rotation axis causes the signal phase to oscillate as the antenna turns, and the phase pattern appears distorted. Moving the axis until that oscillation disappears is a practical way of finding the phase center for a given direction.