Where the standing wave comes from
If a line ends in a load whose impedance differs from the characteristic impedance of the line, part of the wave is reflected. The incident and reflected waves travel in opposite directions and add at different points along the line: at some they reinforce each other and at others they cancel. The resulting pattern, fixed in space, is the standing wave.
Definition
The standing wave ratio (SWR, or VSWR when referred to voltage) is the ratio between the maximum and minimum voltage of that pattern. It is related to the magnitude of the reflection coefficient as follows: VSWR equals one plus that magnitude, divided by one minus that magnitude.
- With a perfect match there is no reflection and the VSWR is one.
- With total reflection, as in a short circuit or an open circuit, the VSWR tends to infinity.
- It is always a real number greater than or equal to one.
What information it keeps and what it loses
VSWR contains only the magnitude of the reflection. It does not say whether the load is capacitive or inductive, or what its phase is. Two very different loads can have the same VSWR. Diagnosing a match requires the full reflection coefficient or its representation on the Smith chart.
What is seen in practice
A high VSWR means that part of the power does not reach the load. In a transmitter, the reflected power can overheat or damage the output stage, which is why protection circuits or isolators are used. On a line, the voltage maxima of the pattern can be higher than those of a matched line, which matters at high power. When measuring at the equipment end, the line loss attenuates the reflection, so a lossy line can appear better matched than the load actually is.
How it is measured
With a network analyzer measuring reflection, or with a reflectometer made up of a directional coupler and detectors. The relationship with return loss is direct: a large return loss corresponds to a VSWR close to one.