What is the spectral range of an infrared camera?

Spectral range is the band of infrared wavelengths to which the detector responds; it defines what can be measured, at what temperatures and through what media.

A band within the infrared spectrum

The infrared extends from the edge of visible red to much longer wavelengths. A camera does not respond to that entire interval, but to a band set by its detector and its filters. That band is its spectral range.

The most widely used bands

Band Approximate interval Typical use
Short-wave (SWIR) About 1 to 3 micrometers Very hot objects, inspection with illumination, some materials
Mid-wave (MWIR) About 3 to 5 micrometers Cameras with cooled detectors, high speed, gas and flame detection
Long-wave (LWIR) About 8 to 14 micrometers Cameras with uncooled detectors for maintenance and buildings

Why these bands are chosen

The atmosphere strongly absorbs radiation at certain wavelengths because of water vapor and carbon dioxide, and it is transparent at others, called atmospheric windows. The MWIR and LWIR bands correspond to these windows, so they allow measurement at a distance without the air absorbing the signal.

How the band affects measurement

  • Object temperature: the wavelength of maximum emission shifts toward shorter wavelengths as temperature rises (Wien’s displacement law). Objects at room temperature emit mainly in the long-wave band; very hot objects are better seen in shorter bands.
  • Solar reflections: solar radiation interferes more in short bands than in the long-wave band.
  • Materials: glass and some plastics transmit or block differently depending on the band; certain flames and gases are visible only in specific bands.
  • Emissivity: it varies with wavelength.

What an engineer sees in practice

Most electrical and mechanical inspections are handled with the long-wave band. The mid-wave and short-wave bands appear in applications that require special filters, speed, high temperatures or seeing through certain media.