What is the P-F curve?

The P-F curve represents how a function deteriorates from the moment a defect becomes detectable (point P) until the equipment fails (point F); the time between the two points is the margin for action.

What it shows

The P-F curve is a schematic of an asset’s deterioration. The vertical axis shows condition or functional capability and the horizontal axis shows time. Point P is the moment when a developing failure becomes detectable by some technique; point F is the functional failure, when the equipment no longer fulfills its function. The time between P and F is the P-F interval.

Why the interval matters

That interval is the window in which an intervention can be planned without an unplanned stoppage. The earlier the defect is detected, the wider the window, and the easier it is to coordinate spare parts, personnel and a scheduled shutdown.

The technique determines where P falls

Point P is not a property of the equipment but of the detection technique. A bearing failure can be detected earlier with vibration analysis than by audible noise, and earlier by noise than by heating. Each technique places P at a different point, so more sensitive techniques widen the interval.

How it is used to decide inspection frequency

If the P-F interval is short, inspections must be frequent enough not to miss it. A reasonable rule is for the period between inspections to be clearly shorter than the interval, to allow time to react after detecting the defect. If the interval is very short or unpredictable, periodic inspection is of no use and continuous monitoring or a different approach is required.

Limitations

  • The interval is not fixed: it varies with load, environment and the way the equipment is operated.
  • Some failures, such as those of electronic components, show no prior signal and have no useful P-F curve.
  • The curve is a conceptual model; intervals are estimated from history and engineering judgment.