Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What is the dissipation factor of insulating oil and what does it reveal?

    The dissipation factor of insulating oil measures the fraction of energy the oil loses as heat when subjected to an alternating field. A rising value indicates the presence of polar contaminants, aging products or conductive particles.

  • What is the duty cycle of a signal?

    The duty cycle of a signal is the fraction of each period during which the signal is at the high level; it is expressed as a percentage and determines the average value of a pulse signal.

  • What is the effective area of an antenna?

    Effective area is the imaginary surface that, multiplied by the power density of the incident wave, gives the power the antenna delivers to a matched load. It is tied to gain and wavelength.

  • What is the EN 50160 standard and what does it describe?

    EN 50160 describes the characteristics of the voltage supplied by public distribution networks, such as frequency, magnitude, dips, interruptions, harmonics and unbalance, and sets how far they must be maintained under normal operating conditions.

  • What is the entry supervisor?

    The entry supervisor is the person responsible for verifying that the conditions for entering a confined space are safe, authorizing the permit, directing operations and canceling the entry when conditions change.

  • What Is the Excitation Current of a Transformer?

    Excitation current is the current a transformer draws from its source with the secondary open and at rated voltage; it creates the core flux and covers the core losses, and its waveform is not sinusoidal because the magnetic material is not linear.

  • What is the far-field region?

    It is the region, at a sufficient distance from the antenna, where the shape of the radiation pattern no longer changes with distance and the wave behaves locally as a plane wave. Gain and pattern measurements are made here.

  • What is the fill factor?

    The fill factor compares a module's actual maximum power with the product of its open-circuit voltage and short-circuit current; it shows how square the I-V curve is and reflects cell quality.

  • What Is the Flash Point of Oil?

    The flash point is the lowest temperature at which the vapors of an oil, heated under defined test conditions, ignite momentarily when a flame is brought near them; it is used to assess fire safety and to detect contamination.

  • What is the GUM uncertainty guide?

    The GUM is an international document that sets out general rules for evaluating and expressing measurement uncertainty, with a method for combining contributions and stating a result with its expanded uncertainty.

  • What Is the Hierarchy of Measurement Standards?

    The hierarchy of measurement standards is the ordering of standards by level of accuracy, from the realization of the unit at a national institute down to working instruments, so that each level is calibrated against the one immediately above it.

  • What Is the Hot Spot in a Winding?

    The hot spot is the hottest zone of the winding, normally in the upper part of the conductors; it sets the aging rate of the insulation and, therefore, the loading capability of the transformer.

  • What is the I-V curve of a module?

    The I-V curve of a photovoltaic module represents the current it delivers at each voltage value across its terminals, under given conditions of irradiance and temperature; from it come the short-circuit current, the open-circuit voltage and the maximum power point.

  • What is the immunity performance criterion?

    The immunity performance criterion is the definition, agreed before the test, of how much degradation of its function is acceptable in a device during and after a disturbance; it turns "failed" or "did not fail" into an objective decision.

  • What is the input impedance of an instrument?

    The input impedance of an instrument is the load it presents to the circuit being measured; if it is not much higher than the source impedance, the instrument itself alters the signal it is meant to measure.

  • What is the interface defined by IEEE 488?

    IEEE 488 defines a parallel communication bus between instruments and a controller, known as GPIB or HP-IB, which lets you send commands to and read results from several units connected to the same cable.

  • What Is the Interfacial Tension of Oil?

    Interfacial tension is the force of attraction at the contact surface between oil and water; it falls when the oil accumulates polar oxidation compounds, which makes it an early indicator of aging.

  • What Is the International System of Units?

    The International System of Units, or SI, is the measurement system used worldwide. It is based on seven base units, defined from constants of nature, from which all other units are derived.

  • What is the international temperature scale?

    The international temperature scale is a practical scale, defined by agreement, that assigns temperature values to reproducible fixed points and specifies how to interpolate between them with defined instruments, in order to approximate thermodynamic temperature.

  • What is the International Vocabulary of Metrology?

    The International Vocabulary of Metrology, known as the VIM, is the document that defines the fundamental terms of metrology, such as quantity, calibration, traceability and uncertainty, so that they are used with the same meaning everywhere.

  • What is the ISM band?

    ISM bands are frequency ranges set aside internationally for industrial, scientific and medical applications that use radio frequency energy for purposes other than communication. Many short-range communication devices share them under certain conditions.

  • What Is the K-Factor of a Transformer?

    The K-factor quantifies how much additional heating a load with harmonics produces in a transformer; a K-rated transformer is designed to withstand nonlinear loads with reduced eddy-current losses.

  • What Is the Loss Factor of a Dielectric?

    The loss factor, also called tan δ or dissipation factor, is the ratio between the resistive current (which turns into heat) and the capacitive current flowing through a dielectric under alternating voltage.

  • What is the lower explosive limit?

    The lower explosive limit (LEL, or LIE in Spanish) is the minimum concentration of a flammable gas or vapor in air at which the mixture can ignite; below it, the mixture is too lean to burn.

  • What is the maximum permissible error of an instrument?

    The maximum permissible error is the extreme value of the indication error that a specification, standard or requirement accepts for an instrument. If the measured error, taking its uncertainty into account, exceeds that limit, the instrument does not comply.

  • What is the maximum power point?

    The maximum power point is the point on the I-V curve where the product of voltage and current is highest; the inverter searches for it continuously with a tracking algorithm because it shifts with light and temperature.

  • What is the MIL-STD-810 military method and what does it evaluate?

    MIL-STD-810 is a U.S. military environmental engineering standard that defines laboratory methods for evaluating how well equipment withstands the environments it will face during its life cycle.

  • What Is the National Frequency Allocation Table (CNAF)?

    The Cuadro Nacional de Atribución de Frecuencias (National Frequency Allocation Table) is the regulatory document that indicates, band by band, which radiocommunication services may use it in Mexico and under what condition.

  • What Is the Negative-Sequence Component in a Three-Phase System?

    The negative-sequence component is the part of an unbalanced three-phase system that rotates in the opposite direction to the network; it does not exist in a perfectly balanced system, and in motors it produces heating and oscillating torques.

  • What is the noise figure of a receiver or amplifier?

    Noise figure indicates how much the signal-to-noise ratio degrades when a signal passes through a receiver or amplifier: it is the ratio of the input signal-to-noise ratio to the output signal-to-noise ratio, normally expressed in decibels.