- What is system grounding versus equipment grounding?
System grounding connects a point of the circuit, normally the neutral, to ground to set its reference; equipment grounding connects exposed metal parts to provide a return for fault current and protect people.
- What Is the Angular Displacement Between Primary and Secondary?
Angular displacement is the phase angle between the high-side and low-side voltages; it arises because delta and wye connections relate line voltages and winding voltages differently.
- What is the annual degradation of a module?
Annual degradation is the fraction of power a module loses each year of operation. It is usually expressed as a percentage per year and is used to project the long-term production of a system and to understand power warranties.
- What is the arc flash PPE category?
The arc flash PPE category is a grouped level that links a task on a piece of equipment to a minimum arc protection value for clothing and accessories, so that incident energy does not have to be calculated in each case.
- What is the arc resistance of an insulating material?
Arc resistance is the ability of an insulator's surface to withstand an electric arc without becoming conductive; it is expressed as the time the arc takes to form a conductive path across it.
- What is the bandwidth of an oscilloscope?
The bandwidth of an oscilloscope is the frequency at which a constant-amplitude sine wave is displayed attenuated to about seventy percent of its true value, the minus three decibel point, and it marks how far you can trust the measured amplitude.
- What is the basic impulse insulation level?
The basic impulse insulation level, or BIL, is the peak value of the standardized lightning impulse voltage that insulation must withstand in a test.
- What is the bathtub curve?
The bathtub curve describes how the failure rate of a product population varies over time: high at the start, low and nearly constant during useful life, and rising at the end due to wear-out.
- What is the battery management system?
The battery management system (BMS) is the electronics that monitors the cells of a pack, measures voltage, current and temperature, estimates its state, balances the cells and disconnects the battery if it operates outside safe limits.
- What is the burden of an instrument?
Burden, or imposed load, is the power or impedance a measuring instrument adds to the circuit when connected to it; if significant, it alters the quantity being measured and produces a loading error.
- What is the characteristic impedance of a line?
It is the ratio between voltage and current of a wave traveling in a single direction along the line; it depends on the geometry and the dielectric, not on the length, and it determines whether a load produces reflections.
- What is the Código de Red and what does it cover on power quality?
The Código de Red, Mexico's grid code, is the set of Mexican technical provisions on planning, operation and connection that establishes the efficiency, quality, reliability, continuity and safety criteria of the National Electric System. On quality, it sets requirements for voltage, frequency, harmonics and power factor.
- What is the color palette in a thermal image?
It is the rule that assigns a color or shade of gray on the screen to each temperature value in the scene; it changes only the appearance of the image, not the underlying measurement.
- What is the communication mode between vehicle and charger?
The communication mode between vehicle and charger defines how they coordinate to charge safely. In the usual AC mode, the control pilot signal tells the vehicle the maximum available current and the connection status; for DC, digital communication is added.
- What is the comparative tracking index?
The comparative tracking index (CTI) is the maximum voltage, obtained in a standardized test with a contaminating solution, at which the surface of an insulator holds out without forming conductive carbon paths.
- What is the complex dielectric constant?
The complex dielectric constant, or complex relative permittivity, is a complex number whose real part measures the energy stored and whose imaginary part measures the energy dissipated by a material in an alternating field.
- What is the compression point of an amplifier?
It is the power level, input or output, at which the actual gain of the amplifier falls one decibel below its linear gain; it marks the onset of saturation and the practical limit of linear operation.
- What is the conservator tank for?
The conservator tank absorbs the expansion and contraction of the oil, keeps the main tank full and limits the oil surface exposed to air.
- What Is the Cooling Class of a Transformer?
The cooling class is a letter code that describes which fluid cools the transformer and how it circulates, for example oil in natural circulation with natural or forced air; it defines the capacity at each cooling stage.
- What Is the Corona Effect?
The corona effect is a localized electrical discharge in the air surrounding a conductor or a sharp point when the field at its surface exceeds what the air can withstand, without reaching a complete failure.
- What is the coverage factor?
The coverage factor is the number by which the combined standard uncertainty is multiplied to obtain the expanded uncertainty, that is, an interval with a stated level of confidence.
- What is the cutoff frequency of a waveguide?
The cutoff frequency of a waveguide is the minimum frequency at which a mode can propagate through it; below it, the field decays exponentially and carries no power. In a rectangular guide with the dominant mode, it depends on the larger dimension of the cross-section.
- What is the decibel and why is it used in RF?
The decibel is a logarithmic scale for expressing the ratio between two powers. It is used in RF because signals span many orders of magnitude and because cascaded gains and losses add instead of multiplying.
- What is the dew point?
The dew point is the temperature at which, when a gas is cooled at constant pressure, the water vapor it contains begins to condense; it measures how much moisture there is in absolute terms, independently of the gas temperature.
- What is the dielectric frequency response of insulation?
Dielectric frequency response describes how the capacitance and losses of an insulation change as the measurement frequency varies, normally over a wide range extending to very low frequencies. It is used mainly to estimate the moisture and conductivity of cellulose insulation impregnated with oil.
- What Is the Dielectric Strength of an Insulator?
Dielectric strength is the maximum electric field an insulator withstands before it loses its insulating capability and conducts; it is expressed as voltage per unit of thickness and is not a fixed constant of the material.
- What is the dielectric strength of insulating oil and what does it depend on?
The dielectric strength of insulating oil is the maximum electric field intensity it withstands before a disruptive discharge occurs. In practice it depends mainly on water, particles and dissolved gases, more than on the chemical purity of the oil.
- What Is the Difference Between a Temporary Overvoltage and a Transient?
A temporary overvoltage is an increase in RMS voltage lasting several cycles or more; a transient is a very brief, fast waveform disturbance that barely moves the RMS value.
- What is the difference between accuracy, precision and repeatability?
Accuracy indicates how close a measurement is to the true value; precision, how close several repeated measurements are to one another; repeatability is precision under the same conditions and over a short period.
- What is the difference between conducted and radiated emissions?
Conducted emission is the disturbance that equipment injects into its cables, above all into the power network, and it is measured at low frequencies with a stabilization network; radiated emission is what leaves through the air as a field and is measured with an antenna.